ASPIRATORE CHIRURGICO TOBI CLINIC
TOBI CLINIC SUCTION ASPIRATOR
ASPIRATEUR TOBI CLINIC
CHIRURGISCHER ABSAUGER TOBI CLINIC
ASPIRADOR QUIRÚRGICO TOBI CLINIC
28214 - 28215 - 28216 - 28231
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
Made in Italy
0476

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TOBI CLINIC and is the answer not in the manual?

Questions and answers

Summary of Contents for Gima TOBI CLINIC

  • Page 1 ASPIRATORE CHIRURGICO TOBI CLINIC TOBI CLINIC SUCTION ASPIRATOR ASPIRATEUR TOBI CLINIC CHIRURGISCHER ABSAUGER TOBI CLINIC ASPIRADOR QUIRÚRGICO TOBI CLINIC 28214 - 28215 - 28216 - 28231 0476 Gima S.p.A. Via Marconi, 1 - 20060 Gessate (MI) Italy gima@gimaitaly.com - export@gimaitaly.com www.gimaitaly.com...
  • Page 2: Important Safety Rules

    TOBI CLINIC is a surgical aspirator power-fed at 230V ~ / 50Hz, to be used for suctioning body liquids (such as mucus, phlegm and blood) provided with 4 antistatic wheels, two of which with braking device, and a pulling handle.
  • Page 3: Technical Characteristics

    MDD 93/42/EEC Directive and its normatives. CONTRAINDICATIONS: • Before using the TOBI CLINIC, consult the instructions for use: failure to read all the instructions in this manual can be harmful for the patient. •...
  • Page 4: Cleaning The Main Unit

    eNgLIsh CLEANING THE MAIN UNIT: To clean the device external parts always use a cotton cloth dampened with detergent. Don’t use abra- sive or solvent detergents. PARTICULAR CARE SHOULD BE TAKEN TO ENSURE THAT THE INTERNAL PARTS OF THE EQUIPMENT DO NOT GET IN TOUCH WITH LIQUIDS. NEVER CLEAN THE EQUIPMENT WITH WATER.
  • Page 5: Maintenance

    MAINTENANCE The TOBI CLINIC suction equipment does not need maintenance or lubrication. It is, however, necessary to inspect the unit before each use. With regard to training, given the informa- tion contained in the user manual and since it is easy to understand the said device, it doesn’t appear...
  • Page 6 2° case – If both the security system doesn’t work, there is the possibility that liquid comes inside the device, in this case return the device to GIMA technical service. GIMA Srl will provide upon request electric diagrams, components list, descriptions, setting instructions and any other information that can help the technical assistance staff for product repair.
  • Page 7 eNgLIsh WARNING: For proper use, place the aspirator on a flat, stable surface in order to have the full volume of use of the jar and better efficiency of the overflow device. The vacuum jar, during use, must be used in vertical mode, to prevent the action of the backflow valve.
  • Page 8: Risk Of Electromagnetic Interference And Possible Remedies

    This section contains information regarding the conformity of the compliance with the EN 60601-1-2 Standard. The TOBI CLINIC surgical aspirator is an electro-medical device that requires particular precautions regarding electro-magnetic compatibility and which must be installed and commissioned according to the electro-magnetic compatibility information supplied.
  • Page 9 Guidance and manufacturer’s declaration – Electromagnetic Emissions The surgical aspirator TOBI CLINIC is intended for use in the electromagnetic environment specified below. The customers or the user of the surgical aspirator TOBI CLINIC should assure that it’s used in such an environment. Emissions Test Compliance Electromagnetic environment - guidance...
  • Page 10 Guidance and manufacturer’s declaration – Immunity Emissions The surgical aspirator TOBI CLINIC is intended for use in the electromagnetic environment specified below. The customers or the user of the surgical aspirator TOBI CLINIC should assure that it’s used in such an environment. Immunity Test Level indicated by Livello di...
  • Page 11 The surgical aspirator is intended to operate in an electro-magnetic environment where RF irradiated interferences are under control. The client or operator of the TOBI CLINIC device can help prevent electro-magnetic interference by keeping a minimum distance between the portable and mobile RF communication devices (transmitters) and the TOBI CLINIC device, as recommended below, in relation to the radio-communication maximum output power.
  • Page 12 Disposal: The product must not be disposed of along with other domestic waste. The users must dis- pose of this equipment by bringing it to a specific recycling point for electric and electronic equipment. GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies.