Maximum length (fastener)
Fastener diameter (steel stud application)
Fastener diameter (concrete application)
Compression stroke
Maximum fastener driving frequency (Fasteners per hour)
4.2
Bluetooth
Maximum magnetic field strength
Frequency
4.3
Noise information and vibration values
The sound pressure and vibration values given in these instructions have been measured in accordance
with a standardized test and may be used to compare one fastening tool with another. They may be used
for a preliminary assessment of exposure. The data given represents the main applications of the fastening
tool. However, if the fastening tool is used for different applications, with different accessories or is poorly
maintained, the data may vary. This may significantly increase exposure over the total working period. An
estimation of the level of exposure should also take into account the periods of time when the tool is not
actually in use. This may significantly reduce exposure over the total working period. Prescribe additional
safety measures to protect the operator from the effects of noise and/or vibration, such as: maintenance of
the direct fastening tool and its additional equipment or accessories, keeping the hands warm, organization
of work patterns.
Noise emission values determined in accordance with EN 15895
Emission sound pressure level at the workplace (L
Peak sound pressure level at the workplace (L
Sound (power) level (L
WA, 1s
Uncertainty (sound level)
Recoil
Energy-equivalent acceleration, for 1 mm sheet metal
onto concrete C40: (a
hw, RMS(3)
Uncertainty
5
Loading the fastening tool
5.1
Equipment required for driving fasteners
The fasteners are pushed manually on to the fastener guide.
5.2
Inserting the gas can
Every new gas can has a transport lock. Before inserting a new gas can, remove the transport lock.
1. Open the gas can compartment cover.
2. Push the gas can (with metering valve fitted) into the red adapter in the gas can compartment.
3. Close the gas can compartment cover.
5.3
Inserting the battery
1. Check that the contacts on the battery and on the fastening tool are undamaged and free from foreign
objects.
18
English
pC, peak
)
)
GX 2-IE
150 mm
50 mm / 60 mm
with 3.35 mm nail
60 mm / 90 mm
with 3.15 mm nail
20 mm
800
−7.6 dBµA/m
13,553 MHz ... 13,567 MHz
GX 2-IE
)
100 dB(A)
pA, 1s
)
133 dB(C)
104 dB(A)
2 dB(A) / 2 dB(C)
GX 2-IE
4.5 m/s²
0.22 m/s²
2208856
*2208856*
GX 2-IE XL
200 mm
50 mm / 60 mm
with 3.35 mm nail
60 mm / 90 mm
with 3.15 mm nail
20 mm
800
GX 2-IE XL
100 dB(A)
133 dB(C)
104 dB(A)
2 dB(A) / 2 dB(C)
GX 2-IE XL
4.5 m/s²
0.22 m/s²

Advertisement