Ipm Check - LG Therma V ZHBW056A0 Service Manual

Air-to-water heat pump
Table of Contents

Advertisement

1. IPM Check

1. Wait PCB DC voltage is discharged after main power off.
2. Pull out V, V, W COMP connector.
3. Set multi tester to resistance mode.
4. If the value between P and N terminal of IPM is short(0Ω) or open(hundreds MΩ), PCB needs to be replaced.(IPM dam-
aged)
5. Set the multi tester to diode mode.
6. In case measured value is different from the table, PCB needs to be replaced. (PCB damaged).
P
W
V
U
Nw Nv Nu
27
26
25
24
23 22 21
0.4 ~ 0.6 V
P
W
27
26
SPM3
P
W
V
U
Nw Nv Nu
27
26
25
24
23 22 21
- 94 -
V
U
Nw Nv Nu
25
24
23 22 21
0.4 ~ 0.6 V
PFC_IPM check
U, V, W ' R S T
Copyright © 2018 LG Electronics Inc. All rights reserved.
Only training and service purposes.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents