LG Therma V ZHBW056A0 Service Manual page 90

Air-to-water heat pump
Table of Contents

Advertisement

Display
Title
code
23
DC Link Low Volt
28
DC Link High Volt
WARNING
Before checking PCB(Inverter) or each outdoor electric parts, wait for 3 minutes after the power is off. When measuring at standby
state of power supply, after checking the measurement mode of the meter, be careful of the short-circuits with other parts.
n Error Diagnosis and Countermeasure Flow Chart
Is input voltage normal ?
Yes
PCB assembly 1
Power connection normal?
Yes
Is PCB(Inverter) Normal?
Yes
Recheck power and installation
condition
Cause of error
• DC Link Voltage is
below 140 V DC
• DC Link Voltage is
above 420 V DC
No
Check power input voltage
No
Check power connection state
No
Replace PCB assembly 1
- 90 -
Check point & Normal condition
• Check CN_(L), CN_(N) Connection
• Check Input Voltage
• Check PCB DC Link voltage sensor parts
• Check CN_(L), CN_(N) Connection
• Check Input Voltage
• Check PCB DC Link voltage sensor parts
Copyright © 2018 LG Electronics Inc. All rights reserved.
Only training and service purposes.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents