To connect to IP device over TCP, simply start your TCP client program ( such
as Hercules or PuTTY) and specify the IP address of the iP device and the TCP
port. Start the connection ( many programs have a Connect button to start the
connection ) and type iP device console commands such as Help. You should
see the reply to the command on the TCP client terminal window. See page 13
and 14 of this manual for a full list of the console commands available.
Instead of a dedicated client program, it is also possible to use Telnet command
to establish the connection. For example, from Windows command prompt,
type:
telnet <IP Address> <Port>
where <IP Address> is the address of the iP device to connect and <Port> is
the TCP port to use.
Example: telnet 192.168.1.22 33333
Note: If there is no activity on the console for 10 minutes the TCP connection
will be closed automatically.
POWER LINE CONDITIONING
The iP1515-RX. iP1520-RX and iP50-RX feature a patented Hybrid Filter Tech-
nology to clean up and prevent both normal mode (line to neutral) and common
mode (ground line) surges and interference. Many popular power conditioners,
including "series mode" devices are less effective on normal mode and have
almost no protection against common mode events.
Energy surges as great as 6,000 volts are reduced to a maximum of 10.0 volts
between line and neutral and 0.50 volts on the ground line. The RX Series cir-
cuitry includes components that act as a low pass filter which reduces high fre-
quency electromagnetic and radio frequency interference.
This unit also protects against external wiring faults. Relays in the RX prevent
operation in conditions of incorrect hot, neutral or ground wiring or in the event
of dangerously high voltage. If this unit is plugged into an outlet that is not
properly wired—if hot, neutral and ground are not properly connecte—power
will not pass to the receptacles. Therefore, a proper ground connection is re-
quired for this unit to operate. The same safety measure functions when incom-
ing voltage exceeds 155 volts.