Connecting To Shore Power - Maxum 2400 SE Sport Express 2004 Owner's Manual Supplement

Cruiser
Table of Contents

Advertisement

WATER HEATER DAMAGE HAZARD! - Do not energize the water heater electrical circuit
until the heater is COMPLETELY filled with water. The tank is full if water flows from the tap
when the hot water is turned On in the galley. Even momentary operation in a dry tank will
damage the heating elements. Warranty replacements WILL NOT be made on elements or tank
damaged in this manner.
• Standard 110 volt AC systems feature one, 110v/30 amp, shore power receptacle.
• If your boat is equipped with an optional air conditioning system, a second (dual) 30 amp inlet has been installed.
Dual shore power inlets are labeled line 1 and line 2, which corresponds to the line 1 and line 2 master breakers on
the AC panel.
• The optional dual shore power system is designed so that each line is independent of the other.

Connecting to Shore Power

1. Monitor the AC panel's polarity indica-
tor lights as follows:
• A GREEN light illuminating after the
power cord is plugged into the boats
external power receptacle indicates
acceptable electrical power in which
you may energize the main
breaker switches.
• A RED light, however, indicates
reversed polarity, which could cause
electrical system damage and possibly
electrical shock injuries. In this case,
DO NOT energize the main
breaker switches.
2. Turn the AC system On by turning the
main ship/shore breaker to the "DOCK-
SIDE" position.
3. Turn On the master breakers and indi-
vidual component breakers as required.
!
CAUTION!
SINGLE SHORE POWER AC PANEL
Chapter 2: Features/Systems
SHORE POWER
INLET (TYPICAL)
17