Download Print this page

RIB JOLLY ONE AA00220 Manual page 21

Reversible operator with electric limit switches for rolling shutters balanced with springs with manual limit switch

Advertisement

Available languages

Available languages

HOW INSTALL JOLLY ONE WITH ELECTROBRAKE
IMPORTANT: Before install JOLLY ONE check that the shutter is correctly balanced by its screws mounted on the shaft. Verify it manually by opening and closing the shutter.
Spring housing
Shaft
=
After have choosen JOLLY ONE according to the dimensions of the shutter, verify the
diameter of the spring housing and of the shaft, because they must have the same diameter
of the choosen motor.
If they're different use the required adaptor:
ACJ9055 SPRING HOUSING ADAPTER Ø 200-220
ACJ9040 SHAFT ADAPTER Ø 42/60
ACJ9050 SHAFT ADAPTER Ø 48/60
A - Make the holes on the shaft as indicated on the rising above draw (see pict.1). Note:
In case you are mounting a motor on an existing rolling shutter and it is difficult to drill
through the shaft, install the motor as per pic. 3 by drilling a 12 mm hole on centre of
62 mm.
Open the motor and mount it as indicated of continuation.
B - Open the pulley unscrewing the 2 screws (1).
C - Mount JOLLY ONE on the shaft and position the motor up and the limit switch down
(see pict. 3). Fix JOLLY ONE on the shaft using the fixing flange and its screws (2) and
(3) alternatively, (2) and (5) in case the installation is not done with a go-through hole.
D - Reassemble the pulley and re-screw its screws (1).
E - On the last section of the shutters make a hole Ø 12 mm / 0,4 in which allows to fix the
shutter to the pulley of the JOLLY ONE using the proper screws (4).
F - Insert the electrical cable and the releasing cable in the holes on the shaft (see pict. 3)
and execute the electrical connections.
Hole Ø 12 / 0,4 (entry of the release cable)
Electrobrake
=
62 / 2,4
Hole diam. 12 / 0,4 (entry of electric cable)
Hole Ø 12 / 0,4 (in vertical)(only for the cable of the brake)
35 / 1,38
250 / 9,85
Ø 12 / 0,4 (frontal) pass-through hole
450 / 17,7
IMPORTANT
Respect the radius of the curve (at least 15 cm / 5,9 in)
=
Electric Cable
Release Knob
21
Hole Ø 12 / 0,4 (frontal) (entry of electric cable)
=
1
2
3
1
PASS-THROUGH HOLE
1
Measurements in mm/in
2
1
2
4
NOT PASS-THROUGH HOLE
5
3
Measurements in mm/in
G
B

Advertisement

loading