Kamoer KSP-F01A-DC User Manual

Kamoer KSP-F01A-DC User Manual

Dosing pump

Advertisement

KSP‐F01A Dosing Pump
 
 
KSP‐F01A Dosing Pump User Manual 
User Manual 
Version: A/3 
Kamoer Fluid Tech (Shanghai) Co., Ltd. 
www.kamoer.com
 
 
 
1
 
 

Advertisement

Table of Contents
loading

Summary of Contents for Kamoer KSP-F01A-DC

  • Page 1 KSP‐F01A Dosing Pump User Manual    KSP‐F01A Dosing Pump   User Manual  Version: A/3          Kamoer Fluid Tech (Shanghai) Co., Ltd.  www.kamoer.com  ...
  • Page 2: Warranty

    To  obtain  warranty  support,  you  may  contact  our  local  technical  support.  Our  technical support will attempt to diagnose and correct the problem. If the problem  cannot be rectified, our technical support will ask you to return the product. You will  be  asked  to  furnish  proof  of  purchase  to  confirm  that  the  product  is  still  under  warranty.                                    Kamoer is registered trademark of Kamoer Fluid Tech (Shanghai) Co., Ltd. We reserve  the right to improve or alter appearance and technical specifications without notice. ...
  • Page 3 KSP‐F01A Dosing Pump User Manual  Notice  We  have  considered  user  safety  in  the  design  process.  Please  read  this  manual  carefully. Any improper operation may cause damage or danger.      1. Safety  The  product  belongs  to  Active  Products.  To  avoid  danger,  you  should  observe the following rules.   If you find any visible damage, please do not switch on;   Be sure not to add any acid, alkali, or volatile solvents;     Be sure not to use in humid environment, avoid damage by short circuit;   Temperature change or mechanical wear may increase the volume error.
  • Page 4: Product Introduction

    KSP‐F01A Dosing Pump User Manual  1  Product  introduction  1.1 Features   Powerful function with a compact appearance.   Friend man‐machine interface with lcd backlight display and key operation.   Support controlling speed with a speed control knob.   Real time clock, support timing start and stop.   Interval between each run can be set, support cycle run, support time‐span run.   Support flow rate calibration.   Support multiple machine use in a series with expansion cable.    1.2 Parts Name                      1. Button      2. LCD display      3. LCD protective screen      4. Pump head component  5. Speed control knob ...
  • Page 5 KSP‐F01A Dosing Pump User Manual   key: Click to minus one or press to minus ten when setting parameters, or  switch to preview parameters when not in setting mode   key: Click to plus one or press to plus ten when setting parameters, or switch  to preview parameters when not in setting mode  1.4 Display introduction  Run: the field of run page  Delay: the field of delay page  From: the field of start time of period page  To: the field of end time of period page  Clock: the field of clock page  Note:    1.  The  lower  left  corner  of  the  lock  icon  shows  that  the  pump  is  running,  at  this  time it cannot be operated other functions.  2. After a period of time without any operation, the pump will enter standby mode,  backlight off.  1.5 Accessory Name Model Quantity Description See the adapter ...
  • Page 6: Interface Introduction

    KSP‐F01A Dosing Pump User Manual  2 Interface introduction 2.1 Run interface  Run by volume, numbers represent volumes in milliliters,  where large numbers represent integer volume, small  numbers represent decimal volume, and volume settings  range from 0.01 to 9999.99 milliliters.    Run by time, numbers in turn represent hours, minutes and  seconds, the time setting range is 1 second ‐99 hours 59  minutes 59 seconds.    Note: In the idle state, long press "Calibration" for 5 seconds, switch volume  running mode and time running mode.  2.2 Delay interface  The waiting time between each running, the range of delay  time is from 0 second to 99 hours 59 minutes and 59  seconds.  Note: delay 0 seconds, the machine run only once.  2.3 Start time and end time interface in time period From stands for the start time in time  period, To stands for the end time in  time period, pump runs in the time  period and stops outside of the time  period.  2.4 Clock interface Set and see current time. ...
  • Page 7 KSP‐F01A Dosing Pump User Manual  2.5 Calibration interface   The countdown page.        The high digital stands for the integer part of calibration  volume, the short digit stands for the decimal part of  calibration volume, the unit is milliliter.                                                 ...
  • Page 8: Installation

    KSP‐F01A Dosing Pump User Manual  3 Installation  1. Lay on the desktop, plug in the pump    2. Put PVC tube into the joint for plastic  shown as the picture.                                        tube.  3. Immerse the PVC tube inlet into the          4. Power adapter plugged into AC power    fluid container, while put the outlet into        socket, output terminal plugged into  the fish tank (head is around 2 meters).        DC IN socket of the dosing pump.   ...
  • Page 9: Operation Mode

    KSP‐F01A Dosing Pump User Manual  4 Operation mode  The dosing pump can support seven operation modes as below:  Mode  Description  Setting  press the "Manual"  key to start running;  press the "Manual"  key to stop when    Manual  running    Note: Only this  mode support speed  adjust by knob.  Parameters Delay, From and To are 0  After reaching the    setting amount, the  Single  pump will stop.  quantitative    add  Note: After setting,    press “Auto” to run.  Parameter Run is not 0  Parameters From and To are 0  Set amount and  time, then the pump  Cycle  will run cyclically.    quantitative  Note: Press “Auto”  Parameters Run and Delay are not 0  add  to start, and press ...
  • Page 10 KSP‐F01A Dosing Pump User Manual    either From or To is not 0  Set amount and  time, then the pump  parameters Run and Delay are not 0  will run cyclically  during this time.  Cycle    quantitative  The pump will not    add during a  work without the  either From or To is not 0  certain time  time you set.    Note: Press “auto”  to start, and press  “auto” again to    stop. ...
  • Page 11: Flow Rate Adjustment

    KSP‐F01A Dosing Pump User Manual  5 Flow rate adjustment  Only in Manual mode, you can adjust dosing flow rate through turning the backside  rotary knob of the dosing pump.  Note: You can change the flow rate only in manual mode. In other states, the rotary  knob does not change the flow rate immediately. The next time you start the  manual run, the dosing pump will run according to the adjusted position.    6 Calibration  6.1 Overview  Calibration is a process to determine accurate flow rate by using a proper measuring  tool  to  measure  added  volume  during  a  certain  time  period.  (10ml  measuring  cylinder is delivered for free with the machine, for more accurate flow rate, a larger  measuring  cylinder  can  be  used).  Pump  is  needed  to  be  calibrated  under  the  following occasions:   Dosing pump used for the first time;  ...
  • Page 12 KSP‐F01A Dosing Pump User Manual  7 Application  For better understanding customers’ needs and testing our dosing pump’s  performance, our company resorts to senior coral experts to take care of our coral  tanks by using KSP‐F01A dosing pump to add nutrient solution (Ca, Mg, KH etc.)    Tank volume: 360L  Creature: SPS 6;LPS 5;Fish 4;Other 8  Dosing solution:Calcium, Magnesium, KH  Dosing amount:  20ml(take Cal as an example)  Dosing times:4 times /day    How to use:  1. Connect the tubing;  2.  Empty  the  tubing  (manual  operation  emptying,  while  adjusting  the  knob  to  the  appropriate flow rate);  3. Calibrate flow rate;  4. Need to add 20ml per day, drop 4 times; each drop 5ml, interval 6 hours;          5. Press “Auto” to start.   ...
  • Page 13: Maintenance

    Adapter    Output  DC 12V 1A  DC24V 1.9A  power supply  12W  Adding  times  96 times/day‐ one time/4 days          Volume  range  1ml‐9999ml  Precision  <±2%  Working  environment  Temperature 0‐70℃  humidity  10%‐90%(non‐condensable)  Storage    temperature  ‐20℃‐85℃  environment  humidity  10%‐90%(non‐condensable)  dimensions(L*W*H)  200*170*110mm  Weight    660g        Kamoer is registered trademark of Kamoer Fluid Tech (Shanghai) Co., Ltd. We reserve  the right to improve or alter appearance and technical specifications without notice. ...

This manual is also suitable for:

Ksp-f01a-stp

Table of Contents