To obtain warranty support, you may contact our local technical support. Our technical support will attempt to diagnose and correct the problem. If the problem cannot be rectified, our technical support will ask you to return the product. You will be asked to furnish proof of purchase to confirm that the product is still under warranty. Kamoer is registered trademark of Kamoer Fluid Tech (Shanghai) Co., Ltd. We reserve the right to improve or alter appearance and technical specifications without notice. ...
Page 3
KSP‐F01A Dosing Pump User Manual Notice We have considered user safety in the design process. Please read this manual carefully. Any improper operation may cause damage or danger. 1. Safety The product belongs to Active Products. To avoid danger, you should observe the following rules. If you find any visible damage, please do not switch on; Be sure not to add any acid, alkali, or volatile solvents; Be sure not to use in humid environment, avoid damage by short circuit; Temperature change or mechanical wear may increase the volume error.
KSP‐F01A Dosing Pump User Manual 1 Product introduction 1.1 Features Powerful function with a compact appearance. Friend man‐machine interface with lcd backlight display and key operation. Support controlling speed with a speed control knob. Real time clock, support timing start and stop. Interval between each run can be set, support cycle run, support time‐span run. Support flow rate calibration. Support multiple machine use in a series with expansion cable. 1.2 Parts Name 1. Button 2. LCD display 3. LCD protective screen 4. Pump head component 5. Speed control knob ...
Page 5
KSP‐F01A Dosing Pump User Manual key: Click to minus one or press to minus ten when setting parameters, or switch to preview parameters when not in setting mode key: Click to plus one or press to plus ten when setting parameters, or switch to preview parameters when not in setting mode 1.4 Display introduction Run: the field of run page Delay: the field of delay page From: the field of start time of period page To: the field of end time of period page Clock: the field of clock page Note: 1. The lower left corner of the lock icon shows that the pump is running, at this time it cannot be operated other functions. 2. After a period of time without any operation, the pump will enter standby mode, backlight off. 1.5 Accessory Name Model Quantity Description See the adapter ...
KSP‐F01A Dosing Pump User Manual 2 Interface introduction 2.1 Run interface Run by volume, numbers represent volumes in milliliters, where large numbers represent integer volume, small numbers represent decimal volume, and volume settings range from 0.01 to 9999.99 milliliters. Run by time, numbers in turn represent hours, minutes and seconds, the time setting range is 1 second ‐99 hours 59 minutes 59 seconds. Note: In the idle state, long press "Calibration" for 5 seconds, switch volume running mode and time running mode. 2.2 Delay interface The waiting time between each running, the range of delay time is from 0 second to 99 hours 59 minutes and 59 seconds. Note: delay 0 seconds, the machine run only once. 2.3 Start time and end time interface in time period From stands for the start time in time period, To stands for the end time in time period, pump runs in the time period and stops outside of the time period. 2.4 Clock interface Set and see current time. ...
Page 7
KSP‐F01A Dosing Pump User Manual 2.5 Calibration interface The countdown page. The high digital stands for the integer part of calibration volume, the short digit stands for the decimal part of calibration volume, the unit is milliliter. ...
KSP‐F01A Dosing Pump User Manual 3 Installation 1. Lay on the desktop, plug in the pump 2. Put PVC tube into the joint for plastic shown as the picture. tube. 3. Immerse the PVC tube inlet into the 4. Power adapter plugged into AC power fluid container, while put the outlet into socket, output terminal plugged into the fish tank (head is around 2 meters). DC IN socket of the dosing pump. ...
KSP‐F01A Dosing Pump User Manual 4 Operation mode The dosing pump can support seven operation modes as below: Mode Description Setting press the "Manual" key to start running; press the "Manual" key to stop when Manual running Note: Only this mode support speed adjust by knob. Parameters Delay, From and To are 0 After reaching the setting amount, the Single pump will stop. quantitative add Note: After setting, press “Auto” to run. Parameter Run is not 0 Parameters From and To are 0 Set amount and time, then the pump Cycle will run cyclically. quantitative Note: Press “Auto” Parameters Run and Delay are not 0 add to start, and press ...
Page 10
KSP‐F01A Dosing Pump User Manual either From or To is not 0 Set amount and time, then the pump parameters Run and Delay are not 0 will run cyclically during this time. Cycle quantitative The pump will not add during a work without the either From or To is not 0 certain time time you set. Note: Press “auto” to start, and press “auto” again to stop. ...
KSP‐F01A Dosing Pump User Manual 5 Flow rate adjustment Only in Manual mode, you can adjust dosing flow rate through turning the backside rotary knob of the dosing pump. Note: You can change the flow rate only in manual mode. In other states, the rotary knob does not change the flow rate immediately. The next time you start the manual run, the dosing pump will run according to the adjusted position. 6 Calibration 6.1 Overview Calibration is a process to determine accurate flow rate by using a proper measuring tool to measure added volume during a certain time period. (10ml measuring cylinder is delivered for free with the machine, for more accurate flow rate, a larger measuring cylinder can be used). Pump is needed to be calibrated under the following occasions: Dosing pump used for the first time; ...
Page 12
KSP‐F01A Dosing Pump User Manual 7 Application For better understanding customers’ needs and testing our dosing pump’s performance, our company resorts to senior coral experts to take care of our coral tanks by using KSP‐F01A dosing pump to add nutrient solution (Ca, Mg, KH etc.) Tank volume: 360L Creature: SPS 6;LPS 5;Fish 4;Other 8 Dosing solution:Calcium, Magnesium, KH Dosing amount: 20ml(take Cal as an example) Dosing times:4 times /day How to use: 1. Connect the tubing; 2. Empty the tubing (manual operation emptying, while adjusting the knob to the appropriate flow rate); 3. Calibrate flow rate; 4. Need to add 20ml per day, drop 4 times; each drop 5ml, interval 6 hours; 5. Press “Auto” to start. ...
Adapter Output DC 12V 1A DC24V 1.9A power supply 12W Adding times 96 times/day‐ one time/4 days Volume range 1ml‐9999ml Precision <±2% Working environment Temperature 0‐70℃ humidity 10%‐90%(non‐condensable) Storage temperature ‐20℃‐85℃ environment humidity 10%‐90%(non‐condensable) dimensions(L*W*H) 200*170*110mm Weight 660g Kamoer is registered trademark of Kamoer Fluid Tech (Shanghai) Co., Ltd. We reserve the right to improve or alter appearance and technical specifications without notice. ...