SERVICE M - serie - range - série Animo Animo Hot water boiler Service enclosure Animo...
Page 2
Animo Troubleshooting M-range for service technician General Before attempting to locate the defect, check th at all parts are still in place. For this purpose, remove the rear partition of the appliance and check that all printed circuit boards, connectors, wiring groups and hoses are still properly fitted.
Page 3
Animo Troubleshooting guide coffee making selection Symptom: Possible cause: Action: The descale indicator light has The scaling deposits in the heat- Descale the appliance, see come on. ing system exceed the set limit. chapter 5.2 Descaling. The descale indicator light...
Page 4
Animo 2.2 Troubleshooting guide M100W and MT100W Troubleshooting guide water boiler Symptom: Possible cause: Action: After filling until the max. Level The dry-boil protection has been Switch the dry-boil protection the heating does not come on. switched off. back on.
Page 5
Animo Troubleshooting guide M200, M202, MT200, MT200v, M200W, M202W, MT200W and MT202W Troubleshooting guide coffee making selection Symptom: Possible cause: Action: The appliance is not working The fuse in the fuse box has Replace the fuse or reset it. and the lamps in the switch are...
Page 6
Animo Troubleshooting guide coffee making selection Symptom: Possible cause: Action: E1 (filling time error) Water level does not reach Check water supply. Fully open maximum level within 90 sec. tap. Increase the water pres- sure. Check the water supply speed. The magnetic valve must admit approx 1l./min.
Page 7
Animo Troubleshooting guide coffee making selection Symptom: Possible cause: Action: E8 (minimum water sensor Minimum water sensor is deacti- Check water supply. Fully open error) vate during the brewing process. tap. Increase the water pres- Reservoir does not refill. sure. Check the water supply flow.
Page 8
Animo Troubleshooting guide water boiler Symptom: Possible cause: Action: Water boiler does not fill and The system switches off when the Open the water supply tap com- switches off. [Maximum filling time filling valve stays open for a period pletely. Check the connection error] longer than 4,5 minute.
Page 9
Animo Animo B.V. Headoffice Dr. A.F. Philipsweg 47 P.O. Box 71 9400 AB Assen The Netherlands Tel. no.+31 (0)592 376376 Fax no.+31 (0)592 341751 E-mail: info@animo.nl Internet: http://www.animo.nl DUTCH COUNCIL FOR ACCREDITATION Accredited by the Dutch Council for Certification Rev. 0 11/01 Art.nr 09839...