Page 1
5-TON ELECTRIC LOG SPLITTER SAFETY & OPERATING INSTRUCTIONS Model: PILOT 5TE DR Power Equipment Serial No. Toll-free phone: 1-800-DR-OWNER (376-9637) Order No. Website: www.DRpower.com Read and understand this manual and all instructions before operating the DR 5-TON ELECTRIC LOG SPLITTER.
Additional Information and Potential Changes DR Power Equipment reserves the right to discontinue, change, and improve its products at any time without notice or obligation to the purchaser. The descriptions and specifications contained in this manual were in effect at printing. Equipment described within this manual may be optional.
Labels Your DR 5-TON ELECTRIC LOG SPLITTER carries prominent labels as reminders for its proper and safe use. Shown below are copies of all the Safety and Information labels that appear on the equipment. Take a moment to study them and make a note of their location on your Electric Log Splitter as you set up and before you operate the unit.
Page 4
The ram should not move during the 4th cycle and should remain fully retracted. Visit our website at www.drpower.com, call 1-800-DR-OWNER (376-9637), or call a qualified hydraulic mechanic for assistance to replace worn components.
Page 5
Never open the switch box or motor cover. Never attempt any electrical repairs yourself. If in doubt, consult a qualified electrician, visit our website at www.DRpower.com or contact DR Power Equipment for toll-free support at: 1-800-dr-owner (376-9637) for help or information.
Page 6
No list of warnings and cautions can be all-inclusive. If situations occur that are not covered by this manual, the operator must apply common sense and operate this DR 5-TON ELECTRIC LOG SPLITTER in a safe manner. Contact us at www.DRpower.com or call 1-800-DR-OWNER (376-9637) for assistance.
Chapter 2: Setting Up the DR 5-TON ELECTRIC LOG SPLITTER It may be helpful to familiarize yourself with the controls and features of your DR 5-TON ELECTRIC LOG SPLITTER as shown in Figure 1 before beginning these procedures. If you have any questions at all, please feel free to contact us at www.DRpower.com.
Page 8
Specifications For your own safety, do not connect the log splitter to the power source until the machine is completely assembled and you read and understand the entire instruction manual Motor Electrical requirements 120V, 60Hz Power output 1090W Rated Current Power Cable 5.8 ft Log Capacity...
Be sure to avoid wet conditions. Tip: In cold weather, see “Specifications” in Chapter 2 for hydraulic fluid information and cycle the Ram to warm up the hydraulic fluid. This will provide full power from your DR 5-TON ELECTRIC LOG SPLITTER. CONTACT US AT www.DRpower.com...
Page 10
Read and understand all instructions, safety precautions, and/or warnings listed in “Chapter 1 General Safety Rules” before operating this DR Dual-action electric log splitter. If any doubt or question arises about the correct or safe method of performing anything found in this manual, please contact our Customer Service Representatives at our toll free number: 1-800-DR-OWNER (376-9637).
Page 11
Splitting Note: All logs should be no longer than 20". Do not place your hands on the ends of the log when loading the Log Splitter. This is a very UNSAFE method and could result in injury to your hands (Figure 7).
Page 12
If the log does not split immediately, do not continue the forward thrust of the ram for more than five seconds. This can damage the splitter. Try repositioning the log on the splitter or set the log aside. 3. Hold the Control Lever, moving the Ram towards the Log until the log is split or the cylinder rod stops at its maximum travel position.
4. Lower the machine to the ground, open the Air Bleed Screw and cycle the Figure 12 Ram back and forth 3 or 4 times to purge any air from the hydraulic system (see “Operating the DR 5-TON ELECTRIC LOG SPLITTER” in Chapter 3). CONTACT US AT www.DRpower.com...
Page 14
8. Lower the machine to the ground, loosen the Air Bleed Screw three or four turns counterclockwise and cycle the Ram back and forth 3 or 4 times to purge any air from the hydraulic system (See Operating The DR 5-TON ELECTRIC LOG SPLITTER in Chapter 3).
Bleed any accumulated air from the hydraulic system. The Electric Log Splitter may not be on a level surface. Make sure the voltage at the outlet or extension cord connection to the DR 5-TON ELECTRIC LOG SPLITTER is 110-120VAC.
Chapter 6: Parts Lists and Schematic Diagrams Parts List - DR 5-TON ELECTRIC LOG SPLITTER NOTE: Part numbers listed are available through DR Power Equipment. Ref# Part# Description Ref# Part# Description A0000937966 Motor-1500w Ip54 A0000938007 Cap Nut-M10 A0000937990 Cylindrical Pin-2.5od X 4...
Page 17
Schematic – DR 5-TON ELECTRIC LOG SPLITTER CONTACT US AT www.DRpower.com...
Page 18
to perform tasks normally performed by the DR 5-TON ELECTRIC LOG SPLITTER. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
Page 20
Before performing any repairs or maintenance procedure, unplug the Electric Log Splitter power cord from the power source. Wipe down the DR 5-TON ELECTRIC LOG SPLITTER to remove any moisture, wood chips, and dirt that may have accumulated on the Log Guides and Operating Handle.
Need help?
Do you have a question about the PILOT 5TE and is the answer not in the manual?