Maintenance And Cleaning; Remedy Of Faults - Oase AquaMax Eco 5000 Operating Instructions Manual

Hide thumbs Also See for AquaMax Eco 5000:
Table of Contents

Advertisement

Available languages

Available languages

Maintenance and cleaning

Cleaning the device
Recommendation regarding cleaning:
• Clean the unit as required but at least twice a year.
• When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
• In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
• Do not not use cleaning agents or chemical solutions.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
Cleaning/replacing the impeller unit
How to proceed:
 C
1. Remove screws.
– The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Remove screws.
5. Remove the pump housing including its holding ring, sealing and impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
6. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.

Remedy of faults

Malfunction
Pump does not start
Pump does not deliver
Insufficient delivered quantity
Pump switches off after a short running time
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Excessive loss in the supply hoses
Excessively soiled water
Water temperature too high
Remedy
Check mains voltage
Clean/check supply lines
Clean strainer casings
Reduce hose length to the necessary minimum,
do not use unnecessary connection parts
Clean strainer casings
Reduce hose length to the necessary minimum,
do not use unnecessary connection parts
Clean pump
Note maximum water temperature of +35 °C