2.24 Preferred iTank location: The iTank must be located on a smooth level
floor of sufficient strength to support the filled weight of the iTank, close to
the water source and a suitable overflow position (see Section 8 - Technical
Specification for filled weight). The iTank must not be installed solely on
beams/joists, doing so will result in permanent damage to tank. The tank
must be supported continuously along its base with no sharp or uneven parts
that could pierce the tank.
It must also be considered that the noise and vibration from the iTank may
be transmitted through the structure the iTank is sited on.
Ensure there is sufficient room above the iTank to allow the removal and
servicing of the pump module and internal float valve and also enough room
around the iTank to access all inlets/outlets.
The unit should be located indoors and be protected from frost damage
(insulation jacket option available).
Cont ...