Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stage:
• Interference immunity:
• Emitted interference:
• Approval:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Ambient temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB051T1 - 11102656
9...30 VDC (HTL)
5 VDC ±5 % (TTL)
9...26 VDC (TTL - R)
≤100 mA
120...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz (pulses ≤1250)
≤250 kHz (pulses >1250)
K1, K2, K0 + inverted
HTL, TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE
ø115 mm
ø11 mm solid shaft
≤200 N axial, ≤350 N radial
EURO flange B10
IP56
≤6000 rpm (T5, mechanical)
≤4500 rpm (T6, mechanical)
4 Ncm
290 gcm
Housing: aluminium die-cast
Shaft: stainless steel
-20...+55 °C
IEC 60068-2-6
Vibration 10 g, 50-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 2 G Ex db eb IIC T5/T6 Gb
Ex db eb IIC T5/T6 Gb
Terminal box
3.5 kg
Baumer_EEXOG9-T1_II_DE-EN (19A2)
2
10
Technical data
24