True TDB-24-48-1-G-1-HC Installation Manual

True TDB-24-48-1-G-1-HC Installation Manual

Underbar refrigeration
Hide thumbs Also See for TDB-24-48-1-G-1-HC:

Advertisement

TRUE
Congratulations!
You have just purchased the finest commercial refrigerator available.
You can expect many years of trouble-free operation.

Table of Contents

Safety Information
Safety Precautions & Proper Disposal ................................................................... 3
Ownership ...................................................................................................................... 4
Cabinet Specification & Location ........................................................................... 4
Notice to Customer ..................................................................................................... 4
Wire Gauge Chart ......................................................................................................... 4
Uncrating ......................................................................................................................... 5
TBB/TDD-1-HC Pallet Removal ................................................................................ 6
Leveling Leg, 6" Leveling Leg & Castor Installation ......................................... 7
Leveling & Sealing the Cabinet to the Floor ...................................................... 8
Electrical Installation & Safety ................................................................................. 9
Standard Accessories & Shelf Installation ........................................................ 10
Direct Draw Draft Arm Installation ..................................................................... 11
CO2 Pressure ................................................................................................................ 11
Kegerator Installation .............................................................................................. 11
General Sequence of Operation .......................................................................... 16
Draft Beer Storage, Handling & Operation ...................................................... 17
Draft Beer Problems & Troubleshooting ........................................................... 18
Changing CO2 Gas Cylinder & Regulator Pressure Adjustment ............... 19
Draft Tower Cleaning ............................................................................................... 20
Condenser Coil Cleaning & Important Warranty Information .................. 21
Stainless Steel Care & Cleaning ............................................................................ 23
Servicing & Replacing Components................................................................... 24
Slide Door Operation ............................................................................................... 25
Warranty
Warranty ....................................................................................................................... 27
TRUE MANUFACTURING CO., INC.
2001 East Terra Lane • O'Fallon, Missouri 63366-4434
(636)-240-2400 • FAX (636)-272-2408 • International FAX (636)272-7546 • (800)-325-6152
Parts Department (800)-424- TRUE • Parts Department FAX# (636)-272-9471
North America - Canada
and Caribbean
Warranty Phone: +1 855 878 9277
Warranty Fax: +1 636 980 8510
Technical Phone: +1 855 372 1368
Warranty Email:
warrantyinquiries@truemfg.com
Technical Email:
service@truemfg.com
7:00 - 7:00 CST Monday - Thursday.
7:00 - 6:00 Friday. 8:00 - 12:00 Saturday.
TEC_TM_114 | REV. A | EN
MANUFACTURING CO., INC.
Mexico
Phone: +52 555 804 6343/44
Toll Free in Mexico: 01 800 202 0687
service-mexicocity@truemfg.com
9:00 am - 5:30 pm M-F
Latin America
Phone: +56 232 13 3600
servicelatam@truemfg.com
9:00 am - 5:30 pm M-F
UNDERBAR REFRIGERATION
INSTALLATION MANUAL
UNDERBAR REFRIGERATION
UK, Ireland, Middle East,
Africa and India
Phone: +44 (0) 800 783 2049
service-emea@truemfg.com
8:30 am - 5:00 pm M-F
04/26/2021
INSTALLATION MANUAL
TDB-24-48-1-G-1-HC
TBB-2-HC
Original Instructions
European Union and
Australia
Commonwealth of
Phone: +61 2 9618 9999
Independent States
service-aus@truemfg.com
Phone: +49 (0) 7622 6883 0
8:30 am - 5:00 pm M-F
service-emea@truemfg.com
8:00 am - 5:00 pm M-F
TD-50-18-S-HC
TBB-3G-S-HC
TDD-4-HC
Page 1 of 28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDB-24-48-1-G-1-HC and is the answer not in the manual?

Questions and answers

Summary of Contents for True TDB-24-48-1-G-1-HC

  • Page 1: Table Of Contents

    TRUE MANUFACTURING CO., INC. 2001 East Terra Lane • O’Fallon, Missouri 63366-4434 Original Instructions (636)-240-2400 • FAX (636)-272-2408 • International FAX (636)272-7546 • (800)-325-6152 Parts Department (800)-424- TRUE • Parts Department FAX# (636)-272-9471 North America – Canada Mexico UK, Ireland, Middle East,...
  • Page 2 You have selected one of the finest commercial refrigeration units made. It is manufactured under strict quality controls with only the best quality materials available. Your TRUE cooler, when properly maintained, will give you many years of trouble-free service. WARNING –...
  • Page 3: Prior To Installation Ownership

    • Phillips screwdriver a professional installation is money well spent. • Level Before you start to install your TRUE unit, carefully inspect it for freight damage. If damage is discovered, immediately file a claim Procedure with the delivery freight carrier.
  • Page 4: Tbb/Tdd-1-Hc Pallet Removal

    U N D E R B A R R E F R I G E R A T I O N truemfg.com U N D E R B A R R E F R I G E R A T I O N truemfg.com Installation (cont.) Installation (cont.)
  • Page 5: Electrical Installation & Safety

    Procedure on the left and right inside floor (level should be parallel to voltage requirement. TRUE uses these types of NEMA plugs shown. If you DO NOT have Level the unit front-to-back and side-to-side. the cabinet sides). Level the cabinet.
  • Page 6: Cabinet Setup

    U N D E R B A R R E F R I G E R A T I O N truemfg.com U N D E R B A R R E F R I G E R A T I O N truemfg.com Cabinet Setup Cabinet Setup (cont.)
  • Page 7 U N D E R B A R R E F R I G E R A T I O N truemfg.com U N D E R B A R R E F R I G E R A T I O N truemfg.com Cabinet Setup (cont.) Cabinet Setup (cont.)
  • Page 8: Cabinet Operation

    TRUE dealer or • Pliers recommended service agent. • Silicone Sealer • Good air flow inside your TRUE unit is critical. Take care to • 1/2" Drill bit prevent product from pressing against the sides or back • Drill wall and coming within 4"...
  • Page 9: General Sequence Of Operation

    U N D E R B A R R E F R I G E R A T I O N truemfg.com U N D E R B A R R E F R I G E R A T I O N truemfg.com Cabinet Operation (cont.) Cabinet Operation (cont.)
  • Page 10: Draft Beer Problems & Troubleshooting

    U N D E R B A R R E F R I G E R A T I O N truemfg.com U N D E R B A R R E F R I G E R A T I O N truemfg.com Cabinet Operation (cont.) Cabinet Operation (cont.)
  • Page 11: Maintenance, Care & Cleaning

    Beer Tap Cleaning Kit – Required Tools regularly. Flushing the draught dispenser with only water is not Condenser Coil Cleaning enough to maintain cleanliness. True recommends cleaning the draught dispenser whenever changing to a fresh keg. When using electrical appliances, basic safety precautions should...
  • Page 12: Stainless Steel Care & Cleaning

    COVERED BY WARRANTY! based products to clean stainless steel surfaces. Avoid build-up of hard stains by cleaning frequently. Use If you have any questions, please contact your local TRUE cleaners at the recommended strength (alkaline chlorinated or Stainless Steel Opponents Manufacturing Service Department.
  • Page 13: Cabinet Adjustments, Servicing & Component Replacement

    Fig. 5. Fig. 6. Align the left edge of the right door with the left edge of the True logo. Align the right edge of the left door with the right edge of the TRUE logo. • Unplug the refrigerator/freezer before cleaning or making any repairs.
  • Page 14: Warranty

    Warranty Claims All claims for labor or parts must be made directly through TRUE. All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the existence of the alleged defect.
  • Page 15 www.truemfg.com Page 28 of 28 04/26/2021 TEC_TM_114 | REV. A | EN...

This manual is also suitable for:

Td-50-18-s-hcTbb-2-hcTbb-3g-s-hcTdd-4-hc

Table of Contents