Sensitivity Adjustment - Omron E2C-CR5B Manual

Inductive proximity sensor e2c
Table of Contents

Advertisement

E2C
Indicators
The operation indicator is lit when the sensing object is near the
sensing distance.
The stability indicator is lit when the sensing object position is
less than 95% or more than 107% of the sensing distance. The
stability indicator indicates the range in which each sensing
object is detected smoothly.

Sensitivity Adjustment

1. Initial Adjustment
After the E2C Amplifier Unit is turned on, adjust the following Sensor according to the status of each indicator without a sensing object.
E2C-Gj4j Single-function Model
E2C-WH4A(F) Multi-function Model
Status
of
Adjustment
Indicators
Operation
Turn the sensitivity adjuster coun-
Lit
terclockwise until the operation in-
dicator turns off.
No adjustment is required.
Not Lit
2. Sensitivity Adjustment
Item
Step
1
Sensing
Sensitivity
---
adjuster
Adjustment
Obtain the
sensing distance
X from the set
distance S
divided by 0.8.
Determine S so
that X will be
less than the
maximum
sensing
distance.
Note: If the E2C Amplifier Unit malfunctions due to radical ambient temperature changes, shorten the distance between the Sensor and
sensing object to 80% maximum of the set distance.
E2C-JC4A Multi-function Model
E2C-Aj4A Multi-function Model
Sensitivity
E2C-Gj4j Single-function Model
2
---
Locate the
Return the
Sensor so that
Sensor to the
the distance
previous position
between the
so that the
Sensor and
distance
sensing object is
between the
X. Turn the
Sensor and
sensitivity
sensing object is
adjuster
S. Secure the
clockwise until
position of the
the operation
Sensor to
indicator is lit.
complete the
sensitivity
adjustment.
Operation indicator
Stable non-
sensing area
Stable sensing
area
Note: Replace the 1.07 value with 1.04 and the 0.93 value with
0.96 for the E2C-X2A.
Status of Indicators
Indicator
Operation
Sensitivity
mode
A
Lit
Lit
B
Lit
Not Lit
C
Not Lit
Not Lit
D
Not Lit
Lit
E2C-WH4A(F) Multi-function Model
3
1
---
Obtain the
sensing distance
X from the set
distance S
divided by 0.8.
Determine S so
that X will be
less than the
maximum
sensing
distance.
Stability indicator
(red)
(green)
Not lit
Lit
Set distance x
approx. 1.07
(see note)
Not lit
Set distance
Set distance x
approx. 0.93
Lit
(see note)
Lit
Adjustment
Sensitivity
Turn the sensitivity adjuster
counterclockwise so that the op-
eration indicator turns off and the
stability indicator is lit (i.e., the
E2C Amplifier Unit is in mode D).
No adjustment is required.
2
---
Locate the
Return the
Sensor so that
Sensor to the
the distance
previous position
between the
so that the
Sensor and
distance
sensing object is
between the
X. Turn the
Sensor and
sensitivity
sensing object is
adjuster
S. Secure the
clockwise until
position of the
the operation
Sensor to
indicator is lit.
complete the
sensitivity
adjustment.
E2C
3
7

Hide quick links: