Switching between dynamic and static IP addresses isn't supported while
encoding or decoding. Before you change the IP address, make sure you stop
encoding or decoding.
If you're using PowerStream Plus software to set a static IP address, make
sure the IP address you want to set isn't already allocated to another device on
the network.
When the
Optimized for Desktop
performance, we recommend to simultaneously also set the encoding option
to
(Variable Bit Rate). Using the
VBR
with the
(Constant Bit Rate) encoding option may result in skipped
CBR
frames on the decoder in case a very high target bit rate is set.
Stop all streams before updating the firmware on an encoder. Otherwise, a
Maevex 6152 decoder may not show the streams in the
not identify it as a stream coming from a Maevex encoder (
may not appear beside the stream name). If this happens, first disable (stop)
then enable (restart) the inputs on the encoder. If applicable, also update
(resave) the encoder configuration for future use.
Maevex 6150/6120 – While recording to local or network storage, no warning
appears if device is full or near full. Make sure there's enough available space
on the destination device (USB-based storage or network-based storage)
before starting to record. If the last recorded file is larger than the available
space, the file won't be able to close, and the recorded data will be lost.
Maevex 6150/6120 – After connecting a new local DisplayPort console
display, the Maevex device must be rebooted for the DisplayPort output to be
enabled.
Maevex 6150/6120 – If the resolution of DisplayPort console output is higher
than Full HD (determined by the connected monitor's preferred resolution),
the preview content frame rate will be limited to 15 fps. This limitation has no
impact on the streamed or recorded frame rate.
Maevex 6150/6120 – To be able to record to
unique IP address for your LAN2 recording destination. Depending on the IP
address of the recording destination, the data will be sent on the
output.
LAN2
Maevex 6150/6120 – The control buttons (on the front on the device)
assigned for the start/stop functionality of the recording can control only
manual recording. Stopping a scheduled recording must be done through
PowerStream Plus. To stop a scheduled recording, access PowerStream Plus
software, then disable the
Release Notes – Matrox
®
Matrox
encoding mode is selected, for best
Optimized for Desktop
Scheduled recording
Maevex™ 6100 Series and Maevex™ 5100 Series
®
encoding mode
Streams list
Maevex source
, make sure to specify a
LAN2
LAN1
option.
, or may
or
5
Need help?
Do you have a question about the Maevex 5100 Series and is the answer not in the manual?