Page 1
ArcSystem Navis 100 Installation Guide Part Number: 7496M2100 Rev A Released: 2020-03...
Page 2
To view a list of ETC trademarks and patents, go to etcconnect.com/ip. All other trademarks, both marked and not marked, are the property of their respective owners. ETC intends this document, whether printed or electronic, to be provided in its entirety.
Table of Contents Overview Document Conventions Help from ETC Technical Services Safety Emergency System Overview Navis 100 Features Channel Settings for RGBW Luminaires Before You Begin Installation Power Disconnect Device Installation Requirements Wiring the Luminaires RJ45 Pinout Information Use of Third-Party Drivers with...
Page 4
Power Up Procedure Identify Emergency Operation and Test Update RGBW Luminaire Firmware RGBW Luminaire DMX Personalities Install Replacement Lens Install Replacement Secondary Optic Maintenance Specifications Accessories Compliance FCC - Part 15 Class A Navis 100 Installation Guide...
Navis 100 luminaires are available for standard or emergency installations. They are intended for use with the F-Drive series of drivers by ETC or other Class 2 or Low Voltage Limited Energy (LVLE) power supplies (48 VDC maximum). Consult the specifications and installation manual for your driver to ensure compatibility.
ETC support website at support.etcconnect.com or the main ETC website at etcconnect.com. If none of these resources are sufficient, contact ETC Technical Services directly at one of the offices identified below. Emergency service is available from all ETC offices outside of normal business hours.
Note: The light source in this luminaire is not replaceable. When the light source reaches its end of life, replace the entire luminaire. Contact ETC Customer Support for assistance. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always...
Emergency System Overview Navis 100 White and Fade to Warm luminaires, when powered by an F-Drive W1 Emergency Driver, are compliant with or conform to the applicable safety standards for emergency applications. For current and complete compliance information, view the Navis 100 datasheet at etcconnect.com/Products/Lighting-Fixtures/ArcSystem- Navis/Documentation.aspx.
Channel Settings for RGBW Luminaires The channel rotary switch on RGBW luminaire assigns the luminaire to a control channel from the control source. (In the F-Drive series of drivers, the Chroma Card is the control source.) When you daisy-chain multiple RGBW luminaires, you must assign each luminaire in the wiring run to a unique channel.
Before You Begin Installation Review the following sections before you begin installing the luminaire. Power Disconnect Device Before installation, make sure that you have a readily accessible input power disconnect device installed ahead of your Navis 100 and the driver. WARNING: Circuits that are installed without an accessible power disconnect device cannot be serviced or operated...
120 Ω resistor. An RJ45 terminator is included with each F-Drive series Chroma Card. To purchase extra RJ45 terminators, please contact your ETC customer service representative and request part number N4086.
Note: Navis 100 RGBW luminaires can only be controlled by the F-Drive series of drivers by ETC. Navis 100 White and Fade to Warm luminaires can be controlled by third-party Class 2 or Low Voltage Limited Energy (LVLE) drivers that provide a maximum of 48 VDC.
Installation This section provides instructions for installing the Navis 100 luminaire. See the installation manual for your driver for information about installing the driver. WARNING: Navis 100 luminaires are NON-IC rated and therefore NOT suitable for installation in direct contact with combustible materials or thermal insulation.
ETC recommends at least 50 cm (20 in) of cable. Spacing for Wall Wash Luminaires If you are installing luminaires with a wall wash trim plate, ETC recommends that you allow minimum spacing as follows to obtain the best coverage: 61 cm (2 ft) between the wall and the center of a luminaire...
Install a Luminaire Note: If you are installing a luminaire with a wall wash trim plate, Install a Wall Wash Luminaire on page 13 for installation instructions. Tools required: small flatblade screwdriver (if installing an RGBW luminaire) • 2.0 mm hex key •...
Page 16
Adjust the tilt and rotation of the luminaire to the approximate final position and use a 2.0 mm hex key to tighten the yellow locking screw on the base of the luminaire to secure the tilt and rotation positions. Be careful not to over tighten the screw. (See Navis 100 Features on page 4 for the location of the locking screw.) Note:...
Install a Wall Wash Luminaire Note: Wall wash luminaires are not intended for use with the Navis 100 Pendant or the Navis 100 Surface Cylinder accessories. Tools required: small flatblade screwdriver (if installing an RGBW luminaire) • 2.0 mm hex key •...
Page 18
Insert the wall wash angle template into the luminaire so that the tabs on the lens holder in the luminaire are firmly seated in the slots in the template. The tilt angle of the luminaire changes to match the angle of the template. Connect a power and data in cable from the driver to the "In"...
Page 19
Remove the wall wash angle template from the luminaire. Attach the magnetic wall wash trim plate to the base of the luminaire so that the angled top of the trim plate fits into the angle of the luminaire. Ensure that the trim plate connects firmly with the three magnets on the base of the luminaire.
Power Up Procedure Note: Incorrect installation of recessed luminaires may cause output to turn on and off periodically due to built-in protection against overheating. Leave the lamp on for several hours to check for overheating caused by improper installation. The driver can overheat even if the lamp is off.
RGBW Luminaire DMX Personalities Navis 100 RGBW luminaires have two personality options: direct (IRGBW) and IRGB. All other Navis 100 luminaires have a single personality: intensity. The personality is set per output card. The IRGB DMX personality provides a means for matching the output from RGBW luminaires to 3000 K White and Fade to Warm luminaires.
Remove the existing lens from the luminaire by twisting the lens counterclockwise to unlock it from the luminaire. ETC recommends that you use a suction cup tool to remove the lens. (A suction cup tool is available from ETC, part number 7496K1011.)
Page 23
Position the replacement lens in the luminaire. Align the tabs on the lens with the appropriate slots in the lens holder. (There are two large tabs and one small tab.) Twist the lens clockwise until it locks into the lens holder. If necessary, reinstall the secondary optic, the finishing ring, or both by snapping the part into the lens holder.
Install Replacement Secondary Optic There are several secondary optic accessories available for the Navis 100 Accessories on page 22 luminaire (see ). Follow these instructions to change a secondary optic. Tool required: Small flatblade screwdriver • Remove the magnetic trim plate from the luminaire. If a finishing ring is installed in the luminaire, remove the finishing ring by sliding a small flatblade screwdriver between the edge of the finishing ring and the side of the luminaire and carefully prying...
Maintenance WARNING: Disconnect the luminaire from all cables and allow it to cool before performing any cleaning and maintenance. AVERTISSEMENT : Débrancher le projecteur de tous les câbles et laisser le refroidir avant d’effectuer un nettoyage ou un entretien. CAUTION: Check for excessive dust or debris in the heat- dissipating fins around the entire luminaire enclosure.
Accessories For a current and complete list of accessories available for the Navis 100 luminaire, see the product data sheet at etcconnect.com/Products/Lighting-Fixtures/ArcSystem- Navis/Documentation.aspx ETC Part Number Beam Angle Lenses 15° 7496K1000 25° 7496K1001 40° 7496K1002 60° 7496K1003 Magnetic Trim Plates*...
Compliance For current and complete compliance information, view the product datasheets at etcconnect.com/Products/Lighting-Fixtures/ArcSystem- Navis/Documentation.aspx. FCC - Part 15 Class A This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received;...
Need help?
Do you have a question about the ArcSystem Navis 100 and is the answer not in the manual?
Questions and answers