Graco Switch 3D Gun Instructions - Parts Manual page 19

Swiveling applicator for robotic sealing applications. for professional use only.
Table of Contents

Advertisement

11. All internal parts and seals can now be removed
from the swivel housing (619). All internal gaskets
and seals should be replaced if the swivel chamber
is dismantled. See F
619
F
. 19
IG
12. The solenoid valves and manifold can be accessed
by removing the cover (612) and removing the four
M3 screws (611). The cable connectors (723) can
be unplugged and the solenoid valves (613) can be
removed by their attached screws. See F
With all the parts removed, clean all the parts that will be
used again. Clean parts with a compatible solvent for
each part. Discard parts not needed for reassembly.
NOTE: Refer to Parts page 24 for additional information
and spare parts numbers
3A8004B
. 19.
IG
. 20.
IG
612
723
F
. 20
IG
Repair
611
613
19