Download Print this page

Emerson FB2100 Field Replacement Manual page 6

Flow computer internal solar regulator
Hide thumbs Also See for FB2100:

Advertisement

FB2100/FB2200 Flow Computer Internal Solar Regulator Field Replacement Guide
D301848X012
November 2020
6.
7.
8.
9.
10.
11.
12.
4
You should now be able to pull regulator out of the battery compartment and set it aside.
Take the new (replacement) solar regulator, and if present, remove its termination cover.
Connect wiring as described in
cover off.
Maneuver the new replacement solar regulator between the tabs for the battery
compartment captive fasteners and slide its right edge through the slot on the right side of
the battery compartment. Now carefully move the left edge of the regulator behind the left
captive fastening tab so you can press the regulator into place against the back of the battery
compartment.
Attach the regulator using the screws you removed in Step 4.
Attach the termination cover using the screws you removed in Step 3.
Close the enclosure.
Wiring the Internal Solar
Regulator, but leave the termination

Advertisement

loading

This manual is also suitable for:

Fb2200