8. Screw the housing base [10] with float drain [13] out of the
housing extension [8].
9. Use the mounting tool [16] to screw the float drain [13] out
of the housing base [10].
NOTE
Proper disposal!
Inappropriate disposal of parts and
components, operating and auxiliary
materials as well as cleaning media can
cause environmental damage.
•
Dispose of all parts and components,
operating and auxiliary materials as
well as cleaning media professionally
and in accordance with regional
legal provisions, regulations and
requirements.
•
In case of uncertainties regarding
disposal, always consult a regional
waste management company.
10. Pull the float drain [13] up and out of the housing base [10]
and dispose of it properly.
11. I nsert a new float drain [13] into the housing
base [10] from above.
12. U se the mounting tool [16] to screw the float drain [13] tight
in the housing base [10].