Download Print this page

Victor 6000counts Instruction Manual

Pocket clamp digital multimeter
Hide thumbs Also See for 6000counts:

Advertisement

Quick Links

6000counts
Pocket Clamp Digital Multimeter
Instruction Manual

Advertisement

loading

Summary of Contents for Victor 6000counts

  • Page 1 6000counts Pocket Clamp Digital Multimeter Instruction Manual...
  • Page 2 6000counts Pocket Clamp Multimeter 1. Overview This is a pocket-sized 3 5/6-digit automatic digital meter. It has stable performance, high precision, high reliability, clear reading and overload protection. Driven by AAA 1.5V battery, the instrument adopts large screen LCD display and adopts boost power supply. Even at the edge of 2.3V low battery, it can ensure the high brightness of backlight and flashlight.
  • Page 3 6000counts Pocket Clamp Multimeter 1-11. Attachment: One instruction manual, one certificate, one leather case, one outer packaging box, one pair of test leads, one type K thermocouple TP01 temperature probe, two AAA1.5V batteries. 2.Technical characteristics 2-1. Accuracy: ±(a% of reading + least significant digit), to ensure accuracy Ambient temperature: (23±5)℃, relative humidity <75%, calibration guarantee period from the date of manufacture for one year.
  • Page 4 6000counts Pocket Clamp Multimeter 3.Technical Specifications 3-1.DC voltage (DCV) Accuracy 6000counts Resolution Range 0.001V ±(0.5%+3) 0.01V 600V 0.1V ±(0.8%+10) 1000V Input impedance: 10MΩ ; Overload protection: 6V range is 550V DC or AC peak; the rest is 1000V DC or 750V AC peak.
  • Page 5 6000counts Pocket Clamp Multimeter Input impedance: 10MΩ ; standard sine wave and triangle wave frequency response is 40Hz-1kHz; other waveform frequency response is 40Hz-200Hz; The specific operations are as follows: 1. Insert the black test lead into the “COM” jack and the red test lead into the “V/Ω /Hz” jack.
  • Page 6 6000counts Pocket Clamp Multimeter same time, the measurement reading will be wrong. 2.In the current measurement state, the measuring probe between “VR” and “COM” should be unplugged due to the large measuring current. Note: 1) The maximum input current is 600A (depending on the red pen insertion position), and an excessive current will display OL.
  • Page 7 6000counts Pocket Clamp Multimeter 3-5. Diode and continuity test Range display value test condition Forward DC current is about 1mA, open circuit Diode forward voltage drop voltage is about 3V The buzzer sounds long and the resistance of Open circuit voltage is about 3V, press "SELECT"...
  • Page 8 6000counts Pocket Clamp Multimeter 3. Then connect the test leads across the capacitors under test. Note: 1) When measuring capacitance with 10nF file, there may be residual reading on the screen display value. This number is the d istributed capacitance of the test pen. It is an accurate reading and can be subtracted after measurement.
  • Page 9 6000counts Pocket Clamp Multimeter 4) It is forbidden to input voltage values exceeding 250V DC or AC peak to avoid damage to the meter. 3-8. Temperature measurement ( °C/°F) Accuracy 6000counts Resolution Range ±(1.0%+5)<400℃; ±(1.5%+15)≥400℃ (-20-1000 )℃ 1℃ ±(0.75%+5)<750℉; ±(1.5%+15)≥750℉...
  • Page 10 6000counts Pocket Clamp Multimeter 4. Operation panel instructions 1 . The clamp head measures vertically through the center of the hole. 2. Product model label position. 3. RANGE is the manual range conversion button, which is the REL relative measurement function when testing the capacitance file.
  • Page 11 6000counts Pocket Clamp Multimeter “APO” symbol on the screen disappears and the auto power off function will be canceled. 6. Troubleshooting If your instrument does not work, the following method can help you solve the general problem, if the fault still can not be excluded, please contact the service center or dealer.