Page 1
6000Counts Automatic Identification Digital Clamp Multimeter 6000counts Automatic Identification Digital Clamp Meter Instruction Manual...
Page 2
1. Overview The 6000counts is a pocket-sized 3 5/6-digit RMS auto-scanning digital meter that does not require a dial to select a function. The meter will automatically recognize and measure based on the input voltage/current/resistance/current. It has stable performance, high pr ecision, high reliability, clear reading and overload protection.
Page 3
6000Counts Automatic Identification Digital Clamp Multimeter 1-10. Weight:about 300g(including 1.5V battery) ; 1-11. Attachment: One instruction manual, one certificate, one outer packaging box, one pair of test leads, two AAA1.5V batteries. 2. Technical characteristics 2-1. Accuracy: ±(a% of reading + least significant digit), to ensure accuracy Ambient temperature: (23±5)℃, relative humidity <75%, calibration guarantee period from the date of manufacture for one year.
Page 4
6000Counts Automatic Identification Digital Clamp Multimeter 3.Technical Specifications 3-1.DC voltage / AC voltage automatic scanning test (DCV / ACV) Accuracy 6000counts Resolution Range DC/AC6V 0.001V ±(0.5%+3) DC/AC60V 0.01V DC/700V 0.1V ±(0.8%+10) AC500V Input impedance: 10MΩ ; overload protection: 700V DC or 500V AC peak.
Page 5
6000Counts Automatic Identification Digital Clamp Multimeter ±(2.5%+3) 60MΩ 10kΩ Input impedance: 10MΩ ; overload protection: 700V DC or 500V AC peak. The specific operations are as follows: 1. The boot display is in the automatic scan status "----". 2. Insert the black test lead into the “COM” jack and the red test lead into the “V/Ω ” jack; the test leads are reliably in contact with the test point.
Page 6
6000Counts Automatic Identification Digital Clamp Multimeter 10uF 10nF 100uF 100nF 10mF 10uF ±(5%+3) 60mF 100uF Overload protection: 700V DC, 500V AC peak. 1. The boot display is in the automatic scan status "----". 2. Insert the black test lead into the “COM” jack and the red test lead into the “V/Ω ” jack; the test leads are reliably in contact with the test point.
Page 7
6000Counts Automatic Identification Digital Clamp Multimeter 1. Press the handle 10, slowly open the jaw opening according to the size of the measuring wire diameter, and pass any one of the measured current wires vertically through the center of the clamp head. The meter will automatically switch to the corresponding according to the measured current. As shown in Figure 1, the measured current value and the current polarity of the red test point will be displayed on the screen at the same time.
Page 8
6000Counts Automatic Identification Digital Clamp Multimeter 8. Voltage, resistance, diode, capacitor, buzzer input port; 9. HOLD key is the data hold button, long press for 2 seconds for the flashlight 10. The function selection key SELECT can switch fast buzzer\diode\capacitance measurement;...
Need help?
Do you have a question about the 6000counts and is the answer not in the manual?