U-Line H-677 Manual
U-Line H-677 Manual

U-Line H-677 Manual

Portable air pump
Hide thumbs Also See for H-677:

Advertisement

π
H-677
portable air
pump
1. Read and thoroughly understand this guide and the
safety labels attached to the system.
2. Before operating, be sure of the following:
• The system is plugged into a properly rated,
grounded outlet – see Electrical Power
Requirements.
WARNING: Failure to properly ground the
system could create an electrical shock
hazard.
WARNING: Do not open the unit. Opening the
covers exposes dangerous electrical shock
hazards.
WARNING: Use protective goggles as indicated
when operating the system.
WARNING: Use ear protection as indicated
when operating the system.
3. Fill-Air™ RF Bags are intended only as packaging
material:
WARNING: Do not use the bags as a flotation
device.
WARNING: Do not use the bags as a child's toy.
WARNING: Do not use the bags as a child's
pillow.
PAGE 1 OF 5
1-800-295-5510
uline.com
sAFety INstRUctIONs
4. The system has no customer serviceable parts. If the
system is not functioning properly:
• Be sure to turn the system OFF and unplug the power
cord.
WARNING: Do not attempt to repair or modify
the Uline Portable Air Pump.
WARNING: Do not open the unit.
• It is required that customers use only Rapid Fill®
bags with the Uline Portable Air Pump. We can
assume no responsibility when other materials are
used with the Uline Portable Air Pump, and we will
refuse to service any Uline Portable Air Pump if non
Rapid Fill® bags or parts have been used. Service
includes, without limitation, providing repairs and
maintenance services, supplies and parts.
5. Inspect at regular intervals to ensure that:
• Component hoses and cables are not cut, broken or
damaged.
• All controls and indicators function properly.
WARNING: If operation of the system differs from
the descriptions in this guide, turn the system OFF,
disconnect the main power and contact Uline
customer service at 1-800-295-5510.
6. Operating conditions:
• The Uline Portable Air Pump is designed to work in a
temperature range of 30 º – 110 º F (-1º – 44 º C) with
a maximum non-condensing relative humidity level
of 90%.
1113 IH-677

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H-677 and is the answer not in the manual?

Questions and answers

Summary of Contents for U-Line H-677

  • Page 1 π H-677 1-800-295-5510 uline.com portable air pump sAFety INstRUctIONs 1. Read and thoroughly understand this guide and the 4. The system has no customer serviceable parts. If the safety labels attached to the system. system is not functioning properly: 2. Before operating, be sure of the following: • Be sure to turn the system OFF and unplug the power...
  • Page 2: System Description

    OveRvIeW system DescRIPtION seqUeNce OF OPeRAtION The Uline Portable Air Pump creates unique air-filled 1. After initially loading a Rapid Fill® Bag onto the air dunnage by inflating a bag inside the shipping supply nozzle, the operator places the uninflated package.
  • Page 3: Electrical Power Requirements

    OveRvIeW cONtINUeD electRIcAl POWeR ReqUIRemeNts Electrical power requirements for the Uline Portable Air Pump are as follows: UlINe PORtABle AIR PUmP RecePtAcle tyPe A/c vOltAGe PHAse cURReNt 115 VAC NEMA 5–15R 115 VAC Single Phase 15 Amp Service (U.S. Version) Std.
  • Page 4: System Components

    OveRvIeW cONtINUeD system cOmPONeNts 5. Air Fill Button Pressing and holding this button delivers air to the 1. On/Off switch bag. This switch controls power to the system. It is located 6. Air Hose on the top of the unit. This flexible tubing supplies air from motor to the air 2.
  • Page 5: System Setup

    OPeRAtING INstRUctIONs system set-UP 2. Select the proper size bag and load it on the air 1. Unbox the system. supply nozzle. (See Figure 2) • The system weighs 7 lbs. (3.2 kg). • Slide the air supply nozzle completely into 2. The Uline Portable Air Pump includes: the inflation port on the one-way self-sealing • Uline Portable Air Pump User’s Guide...

Table of Contents