Mitsubishi PLK-J-CU-20S Technical Manual page 35

Industrial sewing machine
Table of Contents

Advertisement

< sequel to OUTPUT SIGNAL >
Code
MSG
Message display output
OP1
Option output 1
OP2
Option output 2
SSW
Halt signal being on output
Sending table's moving output
MOV
signal
OIL1
Oil lubrication output 1
OIL2
Oil lubrication output 2
Air output for the abnormal
SKAR
stitch detection sensor
Output that is judging the
SKCH
abnormal stitch detection
Test output of the abnormal
SKTS
stitch detection
Output where barcode pattern
BDRD
reading is completed
Output where barcode pattern
PKYC
reading is waiting
Abnormal stitch detection NG
SKNG
output
Abnormal stitch detection OK
SKOK
output
Thickness detection NG(+side)
DPNG
output
Thickness detection NG(-side)
DNNG
output
DFOK
Thickness detection OK output
Analog input 0 judgement
ANT0
output
Analog input 1 judgement
ANT1
output
Abnormal stitch detection 2
S2NG
NG output
Abnormal stitch detection 2
S2OK
OK output
Angle for judgement on
S2CH
Abnormal stitch detection 2
output
Trimming axis home position
THP
output
From the library of Superior Sewing Machine & Supply LLC - www.supsew.com
Function
When the message is displayed on the operation panel, MSG output is turned
on.
Do not use
Do not use
SSW is turned on during power supply is on. However, input signal STP turns
on SSW is turned on with blinking.
Turn on during XY table is moving.
When [OILV] setting is ON, OIL1 is output.
Oil lubricate timing set by [OL1C] and [OL1T].
When [OILV] setting is ON, OIL2 is output.
Oil lubricate timing set by [OL2C] and [OL2T].
During automatic sewing, air for stitch abnormality detection is output.
This signal is effective when Program mode [the stitch abnormality detection
(SKCF)] or [the stitch abnormality detection 2 (S2CF)] is on.
SKCH output turns ON when operating checking about abnormality stitch.
This signal is effective when Program mode [the stitch abnormality detection
(SKCF)] is on.
When the sensor turns ON at the angle at which the stitch abnormality is
judged, a test signal is output. This signal is effective when Program mode
[the stitch abnormality detection (SKCF)] is on.
When reading the pattern number with the barcode it will be output. When
sewing is started, the output turns OFF.
When the bar code is ready to read the pattern number, it will be output.
(PKY = ON and Pattern update incomplete)
SKNG output turns ON when there are suspect of abnormality stitch.
This signal is effective when Program mode [the stitch abnormality detection
(SKCF)] is on.
SKOK output turns ON When sewing is completed with no suspected
abnormal stitch detected. This signal is effective when Program mode [the
stitch abnormality detection (SKCF)] is on.
DPNG output turns ON when material thickness is thicker than "Thickness
setting parameter" at the thickness detection (DFTH) of sewing material.
DNNG output turns ON when material thickness is thinner than "thickness
setting parameter" at the thickness detection (DFTH) of sewing material.
DFOK output turns ON when material thickness is within margin of error
about "thickness setting parameter" at the thickness detection (DFTH) of
sewing material.
ANT 0 output turns ON when the input voltage of CON 10 "analog input 0" on
the I / F board is greater than or equal to the program mode ANT 0 [threshold
value setting of analog input 0] setting value
ANT 1 output turns ON when the input voltage of CON 10 "analog input 1" on
the I / F board is greater than or equal to the program mode ANT 1 [threshold
value setting of analog input 1] setting value
S2NG output turns ON when there are suspect of abnormality stitch 2.
This signal is effective when Program mode [the stitch abnormality detection
2 (S2CF)] is on.
S2OK output turns ON When sewing is completed with no suspected
abnormal stitch 2 detected. This signal is effective when Program mode [the
stitch abnormality detection 2 (S2CF)] is on.
S2CH output turns ON when operating checking about abnormality stitch 2.
This signal is effective when Program mode [the stitch abnormality detection
2 (S2CF)] is on.
When the trimming axis is at the home position (within ±10 degrees), the THP
output is ON.
Specifications