Mitsubishi PLK-J-CU-20S Technical Manual page 23

Industrial sewing machine
Table of Contents

Advertisement

4. Timing chart for
[Clamp link setting (CF)] = ON, [Valid Number of clamp setting (FN)] = 4
Clamp input 1
IF1
Clamp output 1
OF1
Clamp output 2
OF2
Clamp output 3
OF3
Clamp output 4
OF4
Note: Halt switch is validated.
5. Timing chart for [Selection of pneumatic pressure two-step (AF2)] = ON
Can not use other function in "Work holder" mode.
Pneumatic pressure
two-step clamp
input signal
A2F
Start
input signal
SRT
Pneumatic pressure
two-step clamp
low pressure output AFL
Pneumatic pressure
two-step clamp
high pressure output AFH
Pneumatic pressure
two-step clamp
eject pressure output AFE
Movement of
sewing machine
From the library of Superior Sewing Machine & Supply LLC - www.supsew.com
ON
1A
ON
2A
ON
3A
ON
4A
ON
ON
ON
ON
ON
ON
ON
ON
ON
3B
ON
4B
ON
ON
ON
ON
ON
ON
7-3
1B
2B
ON
ON
1T
ON

Advertisement