General
These luminaires are used indoors (ta 40 C) on the wall, where
emergency light is needed. Each luminaire must be permanently
connected to the mains power supply, according to Figure 5 (Page 3). In
normal operation the illumination LEDs are lit as well as the green
indicating charge LEDs, when the battery is charging. In case of a mains
power supply failure, the luminaire goes into emergency mode and the
led stripe is powered by the battery. When the mains power supply is
restored the device turns to normal operation.
Non-Maintained / Maintained operation there is an option to select
the non maintained or maintained operation by placing the jumper to
the appropriate place according to the Figure 4 (see page 2).
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or testing must be done
by authorized personnel only.
2. The device must be connected to the mains power supply through
a fuse dependent by the total amount of the line's power load.
3. It is suggested to check every month the indication LED for battery
charging, and by pushing the TEST button to check the emergency
circuit. The led stripe should light as long as the TEST button is
being pressed.
If the luminaire doesn't work as described above,
contact the installer.
4. It is suggested to check every 6 months the minimum autononous
duration by disconnecting the mains power supply. Count the time
that the led strip lights and in case of less time than the nominal
autonomy, the battery must be replaced. If the measured time is
considerably less than the nominal autonomy
In case of battery or led stripe replacement, these must be
replaced by parts of the same type, by the manufacturer or by a
competent person.
5. In case of inactive use for a period greater than 2 months,
battery must be disconnected fully
charged, disconnect the battery
by pulling out the battery's connector. This inactive condition
should not exceed 4-5 months.
6. I s not allowed to discard batteries into common trash bins, they
t i
must be discarded only
in battery recycling points. Do not
incinerate.
The light source contained in this luminaire shall only be
replaced by the manufacturer, his agent or a similar qualified
person.
NOTE! The light source is non-user replaceable.
1
Installation instructions
o
Dismantle the device carefully by using a flat bladed
1
screwdriver.
Pass the mains cables through the hole (point A) and secure it
2
with a suitable bracket (not included) to ensure immobilization
of the cable at a distance of no more than 5cm from the
luminaire's cable entry. ATTENTION!! To maintain the IP rating,
the outer diameter of the power cable must be at least 8.2 mm².
contact the installer.
Mount the plastic base on the wall (the test button must be
3
facing downwards) using the included mounting accessories in
the
points B and C.
4
2
923378005_09_010
Maintained
Non maintained
operation
operation
923378005_09_010
5
Connect the mains cables to the terminal block.
Connect the battery`s cable with the appropriate terminal.
6
7
Refit carefully the removed plastic parts and power on the
device.
NOTE!!
After finishing the installation you must power the luminaire for at
least 24 hours in order to completely charge the battery. The rated
autonomy duration can be achieved after that time.
Accessory for Suspended Ceiling
Mounting Springs
Α-3018
The luminaire can be installed in a suspended ceiling, after the request of the
necessary accessories.
Α-3008 (927300800) Base for recessed mounting on suspended ceiling (Α-3018
Suspended ceiling mounting springs are included).
3
923378005_09_010

Advertisement

loading

This manual is also suitable for:

Gr-9/leds