11. Conducting tests with the appliance tester:
according to DIN VDE 0701-0702, Example 2 - Devices without
a protective conductor (PC II)
Connecting the test object
Connect one end of the test line to the probe socket of the appliance
tester.
Use the crocodile clip to connect the other end of the test line with a
touchable conductive part of the housing of the test object. Make sure
that the crocodile clip makes a good contact.
Connect the mains plug of the test object to the test socket of the
appliance tester.
Switch on the test object with the mains switch.
Switching on the appliance tester
Connect the mains plug of the appliance tester to a properly connected and
functional earthed mains socket. Switch on the appliance tester via the
mains switch. Press the large button in the switch-on display (Fig. 41). The
currently set parameters are displayed in the next screen. These can be
changed, or simply confirmed using the [next] button (Fig. 42).
Please note that the device does not have a real time clock. The
date must be entered anew or accepted.
Fig. 43
Operating manual for the TG uni 1, TG euro 1 and TG euro 1 med appliance tester
Conducting tests in accordance with DIN VDE 0701-0702, Example 2 – Devices without a protective conductor (PC II)
Fig. 44
Pressing the [next] button brings you to the Main menu (Fig. 43).
Here you can enter the „Appliance testing" mode - [Indiv. tests (service)]
button or configure the basic settings of the appliance tester - [Configuration]
button (see Page 9 Point 6.1).
Entering the appliance identification
Press the [Appliance testing] button in the Main menu (Fig. 43). A screen is
displayed requesting entry of the appliance identification. Pressing the [1/A]
button changes the display to allow the entry of a test ID number with a
maximum of 19 digits. This can also be read via a barcode scanner.
Entry of the appliance identification number is not compulsory.
The subsequent entry of the appliance type (Fig. 46) is not compulsory and
is automatically displayed for barcode entry. For manual entry you use the
[1/A] and [OK] buttons to reach this menu.
Press the [OK] button if you do not wish to enter any information here.