Remote Control Of D&B Amplifiers; Error Monitoring; Error Numbers For D12, D6, And E-Pac - B&R PLC PP15 Reference Manual

Table of Contents

Advertisement

B&R PLC PP15 for use with the, d&b Remote network, Reference manual (1.1 EN)
2. Remote control of d&b amplifiers
The PP15 allows remote control of the following objects by recalling a
dedicated preset.
2.1
The PP15 polls all registered amplifiers for errors at cyclical intervals. If
an error occurs in one of the devices, it is displayed on the error page
of the PP15 with an error number and indicated as a general error
message at the"Error" digital output. In addition an error description in
plain text can be requested. If an amplifier does not respond to the
periodic polls, a "PWR/Comm. Loss" error is displayed and also
indicated as a general error message at the "Error" digital output.
2.1.1
Device Errors
No
0
1
2
3
4
5
6
7
8
9
AmpPresets
Standby mode
Mute
Level control from –57.5 dB to +6 dB with 0.5 dB detents
Delay ON/OFF
Delay settings
Filter (CUT, HFA, ...)
Equalizer ON/OFF
Locking "Secondary Masters" (e.g. PC with R1 Remote control
software)

Error monitoring

Error numbers for D12, D6, and E-PAC

Remark
OK
System Error
Program Error
PS Overtemp.
PS Overvoltage
PS Undervoltage
PS Temp. Warn.
PS Error
DSP Error
Remote Error