Digital Inputs (Di) - B&R PLC PP15 Reference Manual

Table of Contents

Advertisement

Terminal block connections - X1 Digital Inputs (DI)
Pin
Description
1
COM si
GND in sink operation,
+24 VDC in source
operation (1*)
2
COM so +24 VDC in sink
operation, GND in
source operation.
(For further details refer
to the B&R manual)
3
DI 1
Preset1/ZoneCall1
4
DI 2
Preset2/ZoneCall2
5
DI 3
Preset2/ZoneCall3
6
DI 4
Preset2/ZoneCall4
7
DI 5
Preset2/ZoneCall5
8
DI 6
Preset2/ZoneCall6
9
DI 7
Preset2/ZoneCall7
10
DI 8
Preset2/ZoneCall8
11
DI 9
Preset2/ZoneCall9
12
DI 10
Preset2/ZoneCall10
13
DI 11
14
DI 12
15
DI 13
16
DI 14
17
DI 15
Poll off (high)/on (low)
18
DI 16
Alarm contact
Tab. 4: X1 Digital Inputs (DI)
B&R PLC PP15 for use with the, d&b Remote network, Reference manual (1.1 EN)
2.3.3
The PP15 is equipped with 16 software-configurable digital inputs to
allow different functions to be triggered within the PP15.
The current drawn at 24 VDC is approx. 4.2 mA for each input.
Inputs DI 1-DI 10 can be used as push buttons in parallel to the keys
0-9 on the front panel. This allows the presets to be remote controlled.
Alternatively, inputs DI 1-DI 12 can be designed as switches (zone call
function). In this configuration, the assigned preset is active as long as
the switch is closed. After that, the last preset selected using the keys on
the front panel is recalled.
Input DI 15 (Poll on/off) can be used to disable continuous monitoring of
the connected amplifiers. This may be necessary if the amplifiers are
temporarily disconnected from the network (CAN-Bus) or the mains.
Input DI 16 (alarm contact) is the input (Preset) with the highest priority.
/ZoneCall11
/ZoneCall12

Digital inputs (DI)

Note:
If no external wiring is required, configure the "Alarm
contact" digital input as high-active N/O contact (normally
open contact).
24 VDC
Poll on/off
Alarm contact(s) 1 ... x
COM si
COM so
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
DI13
DI14
DI15
DI16
Page 10 of 16