Maintenance

Daily cleaning: The motor in use should always be kept clean. No water drops,
cotton etc should be allowed to get into the interior of the motors.
Check on load current: While the motor is in operation, constant care should
be taken to keep the load' current below the rated value.
Operational sounds: During operation of the motor there must be no rubbing
sounds, shrieks or other random noises. Stop the motor immediately and
restart after inspection and corrections have been made.
Check folding handle latch periodically. This is adjustable. To adjust, loosen
the lock nut on the latch and then screw in until a satisfactory tension has
been achieved.
The wheel bearings use seated bearings and require no regular greasing.
NB To minimize vibration and uneven blade wear, rotate plate
every 2 hours.
Failure to do so can lead to premature wear of the flexible coupling
11