Mounting The Panel In The Enclosure - Pepperl+Fuchs VisuNet FLX RM-320P Series Manual

Table of Contents

Advertisement

VisuNet FLX Panel
Mechanical Installation
4.4

Mounting the Panel in the enclosure

Warning!
Risk of injury!
Lifting the device on your own may lead to injury. Do not attempt to lift the device on your own.
Use a crane or have another person help you.
Overheating of the system can result in improper behavior of the software. To avoid overheating
the system, observe the following instructions:
Make sure that the environmental characteristics of the system are observed.
The BPC3200-*/DMU3200-* and the display may only be operated in closed rooms.
The display must not be exposed to direct sunlight.
The ventilation openings of the computing unit and the display unit must not be covered.
When mounting the display, the permissible mounting angle must not be exceeded.
Danger!
Ambient conditions
Do not operate the device outside the specified ambient temperature.
Ensure for the Panel mount option with additional Panel-Mount-Kit that the thickness of
the installation panel is from 1 mm to 3 mm(0.06 inches to 0 inches).
All installation panel surfaces used should be strengthened. Due consideration should be
given to the weight of the VisuNet FLX panel, especially if high levels of vibration are
expected and the installation panel can move. Use the brackets of the Panel Mount Kits, to
increase the strength of the installation panel.
Ensure that all installation tolerances are maintained.
Ensure that the enclosure provides a flat surface area to confirm a proper sealing between
panel and enclosure.
Do not touch the touch screen during the startup of the operating system.
Do not operate the unit when the surface of the touch screen is wet.
If the surface of the touch screen is wet, remove the existing water with a soft cloth before
resuming operation.
Use only the approved equipotential bonding configuration specified in chapter 5.
All nuts of the mounting brackets must be tightened with a torque of 4 Nm.