Pepperl+Fuchs VisuNet FLX RM-320P Series Manual page 15

Table of Contents

Advertisement

VisuNet FLX Panel
Product Description
Data for application in connection with hazardous areas (pending)
EU-type examination certificate
Marking
International approvals (pending)
UL approval
Approved for
IECEx approval
IECEx certificate Certificate in preparation.
IECEx marking
Standards
DM-320P-* (Direct Monitor)
General specifications
Type
Supply
Input current
Power consumption
DC
Indicators/operating means
Display
Type
Screen diagonal
Certificate in preparation.
II 3 G Ex ec [ic] IIC T4 Gc
II 3 D Ex tc [ic] IIIC T85°C Dc
Certificate in preparation.
Ordinary location
acc. UL 61010-1 and UL 61010-2-201
Hazardous location
Class I, DIV 2, GPS A-D
Class II, DIV 2, GPS F-G
Class III
Class I, ZN 2, IIC T4
Class II, ZN 2, IIIC T85°C
Class III
Ex ec [ic] IIC T4 Gc
Ex tc [ic] IIIC T85°C Dc
IEC 60079-0:2017
IEC 60079-11:2011
IEC 60079-31:2013
IEC 60079-7:2015/A1:2017
Direct Monitor
max. 1.5 A, max. 30 W
24 V d. c. (20 ... 28 V d. c.) (SELV/PELV or class 2)
For connections designation refer to the VisuNet FLX manual.
Liquid Crystal Display (LCD) with LED backlight
Configurable display options:
22GT: 54.61 cm (21.5") [temperature class A]
22FC: 54.61 cm (21.5'')
(Display might react sluggishly below 0°C)
19SC: 48.26 cm (19")
15FC: 39.62 cm (15.6")
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents