This manual describes the installation procedures for the American Dynamics model AD1650B MicroPower EP Video Matrix
Switching Systems. The AD1650B is a CCTV surveillance control system having multiple video inputs, multiple video outputs,
and multiple control stations. The AD1650B is capable of controlling a maximum of 128 video input sources such as cameras
and a maximum of 16 video outputs such as monitors and video tape recorders. AD1650B Systems are supplied in completely
configured switching Bays. Only the necessary bay interconnections, the video input and output connections, and any optional
accessory connections need be made prior to operation.
Setup programming and operating instructions for the AD1650B are provided in the System Programming manual, OP1650BSP.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MicroPower EP AD1650B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for American Dynamics MicroPower EP AD1650B

  • Page 1: Installation Instructions

    Switching Systems. The AD1650B is a CCTV surveillance control system having multiple video inputs, multiple video outputs, and multiple control stations. The AD1650B is capable of controlling a maximum of 128 video input sources such as cameras and a maximum of 16 video outputs such as monitors and video tape recorders. AD1650B Systems are supplied in completely configured switching Bays.
  • Page 2 Note: Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable. However, no responsibility is assumed by AMERICAN DYNAMICS for its use; nor for any infringements of other rights of third parties which may result from its use. No license is granted by implications or otherwise under any patent or patent rights of AMERICAN DYNAMICS.
  • Page 3 I I I I N N N N S S S S T T T T A A A A L L L L L L L L A A A A T T T T I I I I O O O O N N N N A A A A N N N N D D D D S S S S E E E E R R R R V V V V I I I I C C C C E E E E If you require information during installation of this product or if service seems necessary, contact the American Dynamics Repair and Service Department at (800) 442-2225. You must obtain a Return Authorization Number and shipping instructions before returning any product for service.
  • Page 5: Table Of Contents

    AD1672 Keyboard to AD1650B ... C-2 AD1676 Keyboard to AD1650B ... C-3 AD2078 Keyboard to AD1650B ... C-4 AD1691 Code Distributor to AD1650B ... C-5 AD2096 Alarm Interface to AD1650B... C-6, C-7 AD1650B System Configurations Single Bay, 32 Camera, 8 Monitor ... C-8 Two Bay, 64 Camera, 8 Monitor ...
  • Page 7: System Description

    System Modules An AD1650B System consists of one or more switching bays with one Central Processing Module, one or more Power Supply Modules, the desired Video Input Modules (VIM) and Video Output Modules (VOM), and appropriate rear panels.
  • Page 8: System Module Descriptions

    The AD1603N Power Supply Module (PSM) converts the input AC power to the necessary DC voltages which are supplied to all the modules in the AD1650B bay. In multiple bay systems, the AD1603N PSM also provides power to bays that do not have a Power Supply Module.
  • Page 9 Looping Video Input Module - AD1609CM The AD1609CM Video Input Module performs video switching in the AD1650B switching bay, similar to the AD1611 VIM. Each module can switch any one of eight video inputs to any video output, or multiple combinations of video outputs, up to eight.
  • Page 11 Certain of these module setup procedures should be made prior to installation and connection of the AD1650B (Section 2). The Video Output Module Display Control and Power Supply Module Vertical Phase Adjustment procedures can be done only after the system is connected and powered up.
  • Page 12: Video Input Module

    1 and 2, and the DIP switch position 1 and position 5 are set to “ON”. TEST NORM Figure 1-1 - AD1626 Video Output Module PCB Layout AD1650B Jumper Position DIP Switch Position do not indicate the...
  • Page 13: Power Supply Module

    The AD1603N Power Supply Module converts the input AC power to the necessary DC voltages which are supplied to all the modules in the AD1650B bay. The AD1603N PSM also includes the Control Code circuitry which supplies code to the remote Receivers and other Control Code accessories.
  • Page 15: System Installation

    SYSTEM INSTALLATION This section of the manual describes the system installation and connection procedures for the AD1650B System. AD1650B Systems are supplied in completely configured switching bays. Only the necessary bay interconnections, the video input and output connections, and any optional accessory connections need be made prior to operation.
  • Page 16: Connections

    Configurations section at the end of this manual. When the system configuration requires more than one rack, the AD1650B bays should be mounted in side-by-side racks as illustrated in the Typical System Configurations. For proper ventilation and ease of service, allow at least 3 feet (1 meter) from the rear of the racks to any wall.
  • Page 17: Control Code Connections

    AD1650B Control Code Connections The Control Code for Receivers, Code Followers/Responders, Code Distributors, Code Translators, and other code-controlled accessories is provided by Control Code Outputs in either the AD1651B, AD1653B, or AD1655 bay. Accessories associated with video inputs 1 through 64 are controlled by the Control Code Output from AD1651B or AD1653B bays.
  • Page 18: System Control Connections

    RS-232 cables with mating connectors are required between the AD1650B and the modem at one end of the link and between the modem and the RS-232 device at the other end. See the Typical System Connections at the end of this manual, pages C-3, C-4, C-6, and C-7, for illustrations of RS-232 device connections.
  • Page 19: System Configurations

    SYSTEM CONFIGURATIONS The following section of this manual provides interconnection information for typical configurations of the AD1650B system. These are organized according to the size and capabilities of systems. System Configurations ......3-2 Single Bay systems .
  • Page 20 These system configurations include varied combinations of AD1650B bays, with different mixtures of modules for power, processor control, Video Input, and Video Output. The different types of bays used in these configurations are:...
  • Page 21: Single Bay Systems

    AD1650B SINGLE BAY SYSTEMS Single bay systems can consist of 56 cameras and 2 monitors, 48 cameras and 4 monitors, 40 cameras and 6 monitors, or 32 cameras and 8 monitors. A complete system is supplied in one AD1651B bay.
  • Page 22 OUT BNC on this VOM as video output number 2. The upper-right OUT BNC on the next AD1626 VOM to the left is assigned as video output number 3, etc., up to video output number 8 on the fourth VOM. AD1650B...
  • Page 23 AD1650B THREE BAY SYSTEMS, 128 CAMERAS x 8 MONITORS Systems for a maximum of 128 cameras and 8 monitors are supplied in three bays. The AD1653B bay contains a power supply, a processor, and monitor modules for monitors 1 through 8. The AD1654 bay contains the camera modules for cameras 1 through 64.
  • Page 24 SYSTEM CONFIGURATIONS AD1650B THREE BAY SYSTEMS, 128 CAMERAS x 8 MONITORS (Continued from prior page) Video Input Connections Each AD1611 VIM in the AD1654 and AD1655 bays includes eight terminated BNC’s for video input connections. The system assigns the video input connected to the top BNC on the right-most AD1626 VIM in the AD1654 bay as input number 1.
  • Page 25 AD1650B TWO BAY SYSTEMS, 24 CAMERAS x 16 MONITORS Systems for a maximum of 24 cameras and 16 monitors are supplied in two bays. The AD1653B bay contains a power supply, a processor, camera modules for cameras 1 through 24, and monitor modules for monitors 1 through 8.
  • Page 26 AD1657 bay VIP panel are connected to all eight “A” monitor inputs of the AD1657 bay VOM panels. If there are less than 16 monitors in the system, leave the remaining VIP panel BNC’s unterminated. DO NOT TERMINATE THE VIP PANELS. AD1650B...
  • Page 27 AD1650B SYSTEM CONFIGURATIONS Video Input Connections Each AD1609CM in the AD1656 bay has eight pairs of looping BNC’s on the back panel for video input connections. Video inputs are connected to one BNC of each pair and looped to the corresponding terminated video input in an AD1611 VIM in the AD1654 bay.
  • Page 28 MONITOR 11 A and 11 B, system monitor 12 is labeled MONITOR 12 A and 12 B, and so on to system monitor 16. (Continue the Video Interconnections on the next page.) 3-10 AD1650B...
  • Page 29 AD1650B Video Interconnections (continued) AD1654 to AD1653B - Connect the top BNC on the AD1654 bay VIP Panel, labeled 1, to the top input BNC of the AD1653B bay VOM panel for system monitor 1, labeled MONITOR 1 A. Connect the BNC labeled 2 on the AD1654 bay VIP panel, to the top input BNC of the AD1653B bay VOM panel for system monitor 2, labeled 2 A.
  • Page 31: Operation

    The following section of this manual describes the powering up and basic operation of the AD1650B system. The complete system setup programming and operating instructions for the AD1650B are provided in the System Programming manual, OP1650BSP. Powering Up ........4-2 Powering the AD1650 bays .
  • Page 32: Operation Powering Up

    AD1654 or AD1656 bay, is powered by the bay that it is connected to (by the Power/Data Interconnection). MICROPOWER CONTROL SYSTEM Figure 4-1 - AD1650B Bay Front Panel (bays with an AD1603N PSM) Ribbon Cable to DATA OUTPUT PANEL for multiple bay interconnect...
  • Page 33: Keyboard Control

    Note: The current state of latching functions such as locks or gates is not discernible from the keyboard. If critical, operator feedback should be provided via the monitor or some other device. SYSTEM PROGRAMMING For full system programming procedures refer to the AD1650B System Programming Manual, OP1650BSPB. OPERATION...
  • Page 34 IF YOU ENCOUNTER ANY PROBLEMS OPERATING THIS UNIT, OR NEED ASSISTANCE, CALL OUR TECHNICAL SUPPORT CENTER: within the United States: 1-800-442-2225 outside the United States: (914) 624-7640...
  • Page 35: Typical System Connections

    Typical System Connections AD1672 Keyboard to AD1650B ..... C-2 AD1676 Keyboard to AD1650B ..... C-3 AD2078 Keyboard to AD1650B .
  • Page 36: Ad1672 Keyboard To Ad1650B

    NOTE: THESE CONNECTIONS, ILLUSTRATING CONTROL OF MONITORS 1 AND 2, ARE TYPICAL OF ONE KEYBOARD. ANY TWO MONITORS CAN BE CONTROLLED BY ONE AD1672 KEYBOARD. MULTIPLE AD1672 KEYBOARDS CAN BE CONNECTED TO AD1650B PORTS TO CONTROL ADDITIONAL MONITORS. Ð LENS Ð...
  • Page 37: Ad1676 Keyboard To Ad1650B

    NOTE : THESE CONNECTIONS ARE TYPICAL OF ONE KEYBOARD. EACH RS232 PORT IS PROGRAMMABLE. BELDEN 8770 OR EQUIVALENT XMIT JJ0007 PGM MON TYPICAL SYSTEM CONNECTIONS AD1676 KEYBOARD TO AD1650B AD1676 HP0047 TP8059 7.5 VOLTS AC 1.5 AMP AD1650B...
  • Page 38: Ad2078 Keyboard To Ad1650B

    TYPICAL SYSTEM CONNECTIONS AD2078 KEYBOARD TO AD1650B AD2078 JJ0007 TP8082 or TP8083 Wall Transformer JJ0007 CONNECTIONS BETWEEN UNITS THAT ARE RS-232 Connect the cable ground NOTE : THESE CONNECTIONS ARE TYPICAL OF ONE KEYBOARD. on the cable assembly to EACH RS232 PORT IS PROGRAMMABLE.
  • Page 39: Ad1691 Code Distributor To Ad1650B

    Connect the cable ground on the cable assembly to one of the four corner screws. TYPICAL SYSTEM CONNECTIONS AD1691 CODE DISTRIBUTOR TO AD1650B RECEIVER S W B AC AC 12 VOLTS AC 10 VA 18 AWG SHIELDED TWISTED PAIR ,...
  • Page 40: Ad2096 Alarm Interface To Ad1650B

    TYPICAL SYSTEM CONNECTIONS AD2096 ALARM INTERFACE TO AD1650B SELECT ABCDEFGH POWER ALARM ABCDEFGH INPUT OUTPUT JJOOO7 XMIT JJOOO7 HP0047 TERMINAL BOX RS-232 PGM MON Connect the cable ground on the cable assembly to one of the four corner screws. 9 10 11 12...
  • Page 41 61 62 63 64 TYPICAL SYSTEM CONNECTIONS DRAWING ILLUSTRATES CONNECTIONS BETWEEN UNITS THAT ARE LESS THAN SEVEN FEET (7') APART 19 20 21 22 23 24 43 44 45 46 47 48 N N C O C M AD2096 PRGM AD1650B...
  • Page 42: Typical System Configurations

    TYPICAL SYSTEM CONFIGURATIONS SINGLE BAY, 32 Cameras, 8 Monitors PROGRAMMING MONITOR RS-232 PGM MON AD1651 CONTROL CODE CONNECTIONS 8 OUTPUTS TO MONITORS MONITOR MONITOR MONITOR MONITOR 32 INPUTS FROM CAMERAS...
  • Page 43: Two Bay, 64 Camera, 8 Monitor

    PROGRAMMING MONITOR RS-232 AD1653 FLYING LEADS, FOR CONTROL CODE CONNECTIONS POWER/DATA INTERCONNECT AD1654 VIDEO INTERCONNECT PANEL TYPICAL SYSTEM CONFIGURATIONS TWO BAYS, 64 Cameras, 8 Monitors MONITOR PGM MON VIDEO INTERCONNECT 64 INPUTS FROM CAMERAS 8 OUTPUTS TO MONITORS MONITOR MONITOR MONITOR...
  • Page 44: Three Bay, 128 Camera, 8 Monitor

    TYPICAL SYSTEM CONFIGURATIONS THREE BAYS, 128 Cameras, 8 Monitors VIDEO INTERCONNECT PANEL AD1655 CONTROL CODE CONNECTIONS, CAMERAS 65-128 DATA INTERCONNECT TO AD1655 BAY PROGRAMMING RS-232 AD1653 FLYING LEADS, FOR CONTROL CODE CONNECTIONS, CAMERAS 1-64 POWER/DATA INTERCONNECT TO AD1654 BAY AD1654 VIDEO INTERCONNECT PANEL 64 INPUTS FROM CAMERAS...
  • Page 45: Two Bay, 24 Camera, 16 Monitor

    PROGRAMMING MONITOR RS-232 PGM MON AD1653 CONTROL CODE CONNECTIONS DATA INTERCONNECT TO AD1657 BAY AD1657 TYPICAL SYSTEM CONFIGURATIONS TWO BAYS, 24 Cameras, 16 Monitors 8 OUTPUTS TO MONITORS MONITOR MONITOR MONITOR MONITOR 8 OUTPUTS TO MONITORS MONITOR MONITOR MONITOR MONITOR C-11 24 LOOPING INPUTS FROM...
  • Page 46: Four Bay, 64 Camera, 16 Monitor

    TYPICAL SYSTEM CONFIGURATIONS FOUR BAYS, 64 Cameras, 16 Monitors PROGRAMMING MONITOR RS-232 AD1653 FLYING LEADS, FOR CONTROL CODE CONNECTIONS POWER/DATA INTERCONNECT AD1654 DATA INTERCONNECT AD1657 FLYING LEADS, FOR CONTROL CODE CONNECTIONS POWER/DATA INTERCONNECT AD1656 PGM MON MONITOR VIDEO INTERCONNECT 64 LOOPING INPUTS FROM AD1656 BAY MONITOR VIDEO...
  • Page 47 C-13...
  • Page 49: Index

    INDEX...
  • Page 50 Video Output Module ......3 SYSTEM PROGRAMMING ..... 4-3 AD1650B...
  • Page 51 AD1650B Three Bays, 128 Camera, 8 Monitor Systems ..3-5 Two Bays, 64 Camera, 8 Monitor Systems ... 3-4 Two Bays, 24 Camera, 16 Monitor Systems ..3-7 TYPICAL SYSTEM CONNECTIONS .
  • Page 53: Declaration Of Conformity

    Manufacturer’s Address: Sensormatic CCTV Systems Division 10 Corporate Drive Orangeburg, New York 10962 USA Sensormatic Electronics Corporation American Dynamics Business Unit State Rd. 110 Km 5.8 Poblado San Antonio Aguadilla P. R. 00690 Declares, that the product(s) listed below: Name/Type:...
  • Page 54 Additional information: These products herein, comply with the requirements of the EMC Directive 89/336/EEC. The equipment was tested in a typical configuration. Orangeburg, NY, USA, 31 January 1996 Dennis Dodrill, Manager Quality Assurance and Technical Services This representative has the technical documentation and the declaration of conformity on file.
  • Page 56: Specifications

    SPECIFICATIONS Supply Voltage: AD1650B: 120VAC, 50/60 Hz ADE1650B: 230V ADK1650B: Power per Bay: 35 watts max. Mounting: Free standing or Rack mount Size per Bay: Desktop - 5.5" H x 14" D x 17" W (140 x 356 x 432 mm) Rack-mount - 5.25"...