Basic Characteristics Data
Model
Circuit method
LCA10S
Flyback converter
LCA15S
Flyback converter
LCA30S
Flyback converter
LCA50S
Single ended forward method
LCA75S
Single ended forward method
LCA100S
Single ended forward method
LCA150S
Single ended forward method
*1
Please refer to Series/Parallel operation in the instruction manual.
*
The value of input current shown is at ACIN 100V and rated load.
*
Switching freguency of flyback converter deperds on input voltage and load factor.
LCA
LCA-16
Basic Characteristics Data
Switching
Input
frequency
current
[kHz]
[A]
80 - 350
0.3
80 - 300
0.4
80 - 400
0.7
200
1.3
190
1.9
160
2.5
170
3.6
Inrush
Fuse
current
protection
Material
[A]
circuit
2
Resistance of line filter
CEM-3
2
Thermistor
CEM-3
3
Thermistor
CEM-3
3
Thermistor
CEM-3
3
Thermistor
CEM-3
5
Triac
CEM-3
6.3
Triac
CEM-3
June 29, 2011
Series/Parallel
PCB/Pattern
operation availability
Single
Double
Series
operation
operation
sided
sided
* 1
Yes
* 1
Yes
* 1
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parallel
* 1
* 1
* 1
* 1
* 1
* 1
* 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LCA10S and is the answer not in the manual?

Questions and answers

Summary of Contents for Cosel LCA10S

  • Page 1 Circuit method protection Single Double Series Parallel Material [kHz] operation operation circuit sided sided LCA10S Flyback converter 80 - 350 Resistance of line filter CEM-3 LCA15S Flyback converter 80 - 300 Thermistor CEM-3 LCA30S Flyback converter 80 - 400 Thermistor...
  • Page 2 AC-DC Power Supplies Open Frame/Enclosed type Instruction Manual Terminal Block LCA-18 Function LCA-18 LCA-18 Input voltage range LCA-18 Inrush current limiting LCA-19 Overcurrent protection LCA-19 Overvoltage protection LCA-19 Output voltage adjustment range Series Operation and Parallel Operation LCA-19 Assembling and Installation Method LCA-20 LCA-20 Installation method...
  • Page 3 Instruction Manual AC-DC Power Supplies Open Frame/Enclosed type lLCA100S 1 Terminal Block lLCA10S AC(L) +Output -Output AC(N) +Output -Output Frame ground +Output -Output +Output -Output AC(L) -Output lLCA150S AC(N) +Output Frame ground lLCA15S AC(L) - +Output AC(L) -Output AC(N) - -Output AC(N) -Output Frame ground...
  • Page 4 2.4 Overvoltage protection unit. LCA10S LCA15S LCA30S Overvoltage protection circuit, clamping the output voltage by (a) When the output voltage is less than 5V. zener diode, is built-in and comes into effect at over 115% of the...
  • Page 5 Instruction Manual AC-DC Power Supplies Open Frame/Enclosed type When the output voltage is more than 12V. Power Supply Power Supply Power Supply Power Supply D1 D2: Please use Schottky Barrier Diode Parallel operation is not possible. Redundancy operation is available by wiring as shown below. Power Supply Power...
  • Page 6 Instruction Manual AC-DC Power Supplies Open Frame/Enclosed type lLCA50S For 3V, 5V, 12V, 15V Normal position (D) mounting (A) mounting (B), (C), (E) mounting (A) - (F) mounting Convection Forced air (0.5m /min) nIn case of metal chassis, keep more than 8mm for the part of to Ambient temperature [ ] insulate between lead of component &...
  • Page 7 Instruction Manual AC-DC Power Supplies Open Frame/Enclosed type lLCA100S lLCA15S LCA30S LCA50S LCA75S LCA100S LCA150S (B), (C), (D) mounting (A) mounting (E) mounting (A) - (F) mounting Convection Forced air (0.5m /min) 30 20 40 30 50 40 60 50 70 60 nKeep isolation distance between screw and internal components, Ambient temperature [ ]...

This manual is also suitable for:

Lca15sLca30sLca50sLca75sLca100sLca150s

Table of Contents