Connecting Electric Controls; Adjustment Of Ec Operating Control Unit; Adjustment Of Pressure Equalisation - Hardi 3500 EXPLORER Operator's Manual

Table of Contents

Advertisement

3500 / 4000 EXPLORER

Connecting electric controls

Connection of display and control panels
Adjust angle and then tighten the holder bracket bolt.
WARNING: To avoid a short circuit, the power must be
disconnected before attaching the BNC connector
plugs tothe connector jacks.
HP 3880 display with
HP 3005 power box
1
15
16
4
18
6
Tractor
Sprayer
13
17
8
7
8
1. HP 3880 display
2. HP 3500 control box
3. HP 3600 control box
for hydraulics
(OPTIONAL)
4. HP 3005 power box
5. HP 3050 sprayer
junction box
6. Fuse (inside)
7. Speed transducer
8. Magnets
Fig 10
See Fig 11 below for typical cabin installation of controls.
Fig 11
8
13
2
OPT
3
18
16
+
5
6
14
10
9
11
12
9. Flow transducer
10.Diode
11.Rotor
12.Flow housing for
operating unit
13.Coaxial cable
14.Power cable
15.BNC connector jack
16.BNC connector plug
17.BNC cover
18.To power supply
The connectors have a bayonet fitting. To attach, locate
guide groove, push and turn.
Either of the connector jacks on the control panels can
be connected first.
Fig 12
9
10
-
11
12
7, 8
Fig 13
Adjustments of EC Operating Control Unit
Before spraying the EC operating unit is adjusted using
clean water (without chemicals).
NOTE! To understand how to activate each func-
tion using the Pilot controller, please carefully read
your Pilot Operators Manual for detailed instructions
1. Choose the correct nozzle for the spray job by turning
the TRIPLET nozzle bodies. Make sure that nozzles
are the same type and capacity. See "Spray Tech-
nique" book for selection guidelines.
2. Turn main ON/OFF switch to ON.
3. Activate distribution valves so all sections are turned
ON.
4. Activate Pressure regulation switch C until emer-
gency handle (3 Fig 15) stops rotating (min pres-
sure).
5. Put the tractor in neutral and adjust the P.T.O. and
thereby the number of revolutions of the pump
corresponding to the intended travelling speed.
Remember the number of revolutions on the P.T.O.
must be kept between 300-600 rpm.
6. Pressure regulation switch C is activated until the
required pressure is shown on the pressure gauge.

Adjustment of Pressure Equalisation

1. Close the first section distribution valve.
2. Turn the first adjusting screw (C1 Fig 14) until the
pressure gauge again shows the same pressure.
3. Adjust the other sections of the distribution valve in
the same way.
NOTE! After initial adjustment of Pressure Equalisation,
further adjustment will only be needed when:
1. You change to nozzles of different capacities.
2. The nozzle output increases as the nozzles wear.
1
4
2, 3(opt)
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

4000 explorer

Table of Contents