The procedure to update the RX-1052 software is accomplished with the use
of the Rotel Upgrade Manager computer communications program.
This software is only for the RX-1052 V03. The V03 version can be determined by
the RDS logo on the front panel, or a small "V03" denoted on the rear panel above
the serial number sticker. Rotel does not take any responsibility for loss of
information or problems resulting from a failed download. Units that fail after a
download may be returned to Rotel for attention under warranty.
Items needed for upgrade:
Windows-compatible PC with serial port connection, or USB-to-serial adapter.
RS232 cable with DB-9 to RJ-45 terminations.
Upgrade software and Rotel Upgrade Manager download program.
Rotel Upgrade Manager Program Installation
1. Download and save the update files from Rotel to a folder on the PC. Make
note of where the files are saved. (example: C:\Temp)
2. From the Windows Start Menu, choose "Run..."
3. When the run window opens, click Browse and locate the folder where the files
were saved to, and select the file named "Rotel Upgrade Manager.exe"
4. Hit OK to run the setup program.
5. Once setup is running, follow the prompts to install the program into the folder
of your choice.
6. When installation is complete, please refer to the upgrade instructions on the
following page.
1
Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109
DATE: January 20, 2011
Software Upgrade Instructions
MODEL: RX-1052 V03

Advertisement

loading

Summary of Contents for Rotel RX-1052 V03

  • Page 1 5. Once setup is running, follow the prompts to install the program into the folder of your choice. 6. When installation is complete, please refer to the upgrade instructions on the following page. Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109...
  • Page 2 “Rotel Upgrade Manager”. 5. Click the Open button. From the Open window, select the current software file to load, and click Open. Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109...
  • Page 3 8. Click the Next button again. The program should now read “Device Initialization OK” followed by “Please Main Power Off and On the Device!” Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109...
  • Page 4 20 minutes to complete, while PCs with built in serial ports typically will complete the process in less than 5 minutes. Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109...
  • Page 5 VIDEO 4 buttons as left and right cursor keys to select SAVE YES to restore all default settings. On power up, the unit will now be in its factory default configuration. Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109...
  • Page 6: Troubleshooting

    Rotel or an authorized Rotel dealer. An incorrect or fault pin configuration on the RJ45 to DB9 upgrade cable can result in this error. Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109...
  • Page 7 5. To remap the com port, from Device Manager right click on the USB to Serial adapter and select Properties. Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109...
  • Page 8 7. On the Advanced menu, there is a drop down menu listing all of the available com ports on the computer. Select an available port, and then press OK to close the menu and save the changes. Rotel of America – 54 Concord St – North Reading, MA 01864 – Ph: 978-664-2870 – Fax: 978-664-4109...