Rotel RSX-1057 Command List

Rotel RSX-1057 Command List

Rs232 controller command list
Hide thumbs Also See for RSX-1057:

Advertisement

Table: RSX 1057 Waveform format expected:
Baud Rate
Parity
19200
Table: RSX 1057 expected format of a request by RS 232 controller:
Start
Count
Device ID
0xFE
0x03
0xC7

Table 1: Type 10 Primary Command List

NOTE: The values in the table below show the exact byte sequence of all requests. The device
will expect the bytes only - no spaces, no delimiter, etc. The controlling device may implement its
own method to download each command sequence. The numerical values in the first column are
Hexadecimal.
RSX 1057 HEX
FE 03 C7 10 00 DA
FE 03 C7 10 01 DB
FE 03 C7 10 02 DC
FE 03 C7 10 03 DD
FE 03 C7 10 04 DE
FE 03 C7 10 05 DF
FE 03 C7 10 06 E0
FE 03 C7 10 07 E1
FE 03 C7 10 08 E2
FE 03 C7 10 09 E3
FE 03 C7 10 0A E4
FE 03 C7 10 0B E5
FE 03 C7 10 0C E6
FE 03 C7 10 0D E7
FE 03 C7 10 0E E8
FE 03 C7 10 0F E9
FE 03 C7 10 10 EA
FE 03 C7 10 11 EB
FE 03 C7 10 12 EC
FE 03 C7 10 13 ED
FE 03 C7 10 14 EE
FE 03 C7 10 15 EF
FE 03 C7 10 16 F0
FE 03 C7 10 17 F1
FE 03 C7 10 18 F2
FE 03 C7 10 19 F3
FE 03 C7 10 1A F4
FE 03 C7 10 1B F5
FE 03 C7 10 1C F6
RSX 1057
RS232 Controller Command List
Valid Data Bits
N
8
Type
Key
0x10
0xXX
Command
RMC Vol+
RMC Vol-
CD
Tuner
Tape
Video 1
Video 2
Video 3
Video 4
Video 5
Power
Vol+
Vol-
Treble+
Treble-
Bass+
Bass-
Stereo
3 Stereo
Pro Logic
DSP
Multi
Dynamic
Rec
OSD Menu
OSD Enter
OSD Right (+)
OSD Left (-)
OSD Up
Stop Bit Value
Handshaking
1
Checksum
0xXX
Command Description
Remote Volume Up
Remote Volume Down
Source CD
Source Tuner
Source Tape
Source Video 1
Source Video 2
Source Video 3
Source Video 4
Source Video 5
Power Toggle
Volume Up
Volume Down
Treble Up
Treble Down
Bass Up
Bass Down
DSP Stereo
DSP Dolby 3 Stereo
DSP Pro Logic
DSP Music
Multi Input
Dynamic Range
Record
OSD Menu
OSD Enter
OSD Right
OSD Left
OSD Up
Data Type
None
String

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RSX-1057 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rotel RSX-1057

  • Page 1 RS232 Controller Command List Table: RSX 1057 Waveform format expected: Baud Rate Parity 19200 Table: RSX 1057 expected format of a request by RS 232 controller: Start Count Device ID 0xFE 0x03 0xC7 Table 1: Type 10 Primary Command List NOTE: The values in the table below show the exact byte sequence of all requests.
  • Page 2 RSX 1057 HEX FE 03 C7 10 1D F7 OSD Down / Dynamic FE 03 C7 10 1E F8 Mute FE 03 C7 10 1F F9 Digital In Select FE 03 C7 10 20 FA Tune / Preset FE 03 C7 10 21 FB Preset Scan FE 03 C7 10 22 FC Surround+...
  • Page 3 RSX 1057 HEX FE 03 C7 10 61 3B dts Neo:6 Cinema FE 03 C7 10 62 3C PLII Panorama FE 03 C7 10 63 3D PLII Dimension Up FE 03 C7 10 64 3E PLII Dimension Down FE 03 C7 10 65 3F PLII Center Width Up FE 03 C7 10 66 40 PLII Center Width Down...
  • Page 4 Table 4: Type 15 Record Source Command List RSX 1057 HEX FE 03 C7 15 02 E1 Record CD FE 03 C7 15 03 E2 Record Tuner FE 03 C7 15 04 E3 Record Tape FE 03 C7 15 05 E4 Record Video 1 FE 03 C7 15 06 E5 Record Video 2...
  • Page 5 RSX 1057 HEX FE 03 C7 16 69 49 Zone 2 Tune FE 03 C7 16 6A 4A Zone 2 Preset FE 03 C7 16 6B 4B Zone 2 Source FE 03 C7 16 6C 4C Zone 2 Mute On FE 03 C7 16 6D 4D Zone 2 Mute Off Table 6: Commands sent with exceptions or modifications required...
  • Page 6 Table 9: Type 32 Zone 2 Volume Direct Command List RSX 1057 HEX FE 03 C7 32 00 FC Zone 2 Volume Min FE 03 C7 32 01 FD Zone 2 Volume 1 FE 03 C7 32 02 FE Zone 2 Volume 2 FE 03 C7 32 03 FF Zone 2 Volume 3 FE 03 C7 32 04 00...

Table of Contents