Requirements for electric connection

Safety precaution
1. Must follow the electric safety regulations when installing the unit.
2. $FFRUGLQJ WR WKH ORFDO VDIHW\ UHJXODWLRQV XVH TXDOL¿HG SRZHU VXSSO\ FLUFXLW DQG DLU VZLWFK
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
 'R QRW SXW WKURXJK WKH SRZHU EHIRUH ¿QLVKLQJ LQVWDOODWLRQ
7. If the supply cord is damaged, it must be replaced by the manufacturer, its service
DJHQW RU VLPLODUO\ TXDOL¿HG SHUVRQV LQ RUGHU WR DYRLG D KD]DUG
8. The temperature of refrigerant circuit will be high, please keep the interconnection
cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
Grounding requirement
1. The air conditioner is the first class electric appliance. It must be properly
grounding with specialized grounding device by a professional. Please make sure
it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used for
other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in all
SROHV VKRXOG EH FRQQHFWHG LQ ¿[HG ZLULQJ
6. Including an air switch with suitable capacity, please note the following table.
Air switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
Type
Compact Split
Model
ACV09000R
ACV12000R
ACH09000R
ACH12000R
31
Required Capacity of
air break switch
10A
1A
0A
13A