1. Provide adequate clearances between the range and adjacent combustible surfaces.
2. Location—Check location where the range will be installed. Check for proper electrical supply, and the
stability of the floor.
3. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface
must be solid and level.
FRONT
VIEW
30"
(762 mm)
Minimum
Minimum to
Minimum to wall
wall on either
1"
on either side of
side of range
(25 mm)
range above
above 35¾"
36'' (914 mm)
height
height.
35¾"
36"
908 mm
(914 mm)
RANGE
OVERALL
DIMENSIONS
48"
(1219 mm)
Maximum
(1245 mm)
Maximum
Door Open
*30" (762 mm) Minimum clearance between the top of the cooking surface and the bottom of an
unprotected wood or metal cabinet
24"(610 mm) minimum when bottom of wood or metal cabinet is protect by not less than 1/4"
flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015"
steel, or 0.024"
(0.6 mm)
0" (0 mm) clearance is the minimum for the rear of the range. Follow all dimension requirements provided
above to prevent propery damage, potential fire hazard, and incorrect countertop and cabinet cuts.
To eliminate the risk of burns or fire be reaching over heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced
by installing a range hood that projects horizontally a minimum of 5"
cabinets.
4
30"
(762 mm)
Minimum to
cabinets on
18"
either side of
(457 mm)
range.
30"
0" (0 mm) clearance below cooking top and at rear of range.
(762 mm)
25- 3/4"
30"
28-3/4" (730.3 mm) with door handle
(654 mm)
26-3/8" (670 mm) without door handle
(762 mm)
49"
29- 7/8"
(759 mm)
aluminum or 0.020"
SIDE
VIEW
15"
13"
381 mm
330 mm
Maximum depth
for cabinets
above range top.
25"
635 mm
36
1/8"
(914 mm)
(3 mm)
copper.
(0.5 mm)
Centerline of
range
All dimensions for electrical outlet location
shows where the electrical outlet must be
for flush to the wall installation.
11"
(279 mm)
22"
(559 mm)
6"
(152 mm)
2-5/8" (67 mm) for models
equipped with warmer drawers
3-1/2" (89 mm) for models
equipped with storage drawers
beyond the bottom of the
(127 mm)
are maximum.
Dashed cubed area
installed
Wall
Edge
(6 mm)
stainless
(0.4 mm)