Operating Instructions Restroom Cleaning Mode - Prochem RC2700 CR2 Safety, Operation & Maintenance Instructions

Multi-surface extractor
Table of Contents

Advertisement

OPERATING INSTRUCTIONS RESTROOM CLEANING MODE

Hard surface Cleaning with Chemical feed system
The chemical feed system is designed to deliver accurate chemical dilution for touchless surface cleaning.
Fill the solution tank of your CR2 with sufficient water for the task at hand.
Connect solution hose and accessory pressure gun.
Select the appropriate tip and install on the cap of the chemical feed.
Place a bottle into bottle holder. Take the feed tube attached to the cap and place it inside the bottle.
Take the cap of the feed tube and attach it onto the bottle of chemical to secure it in place.
Turn the chemical dispensing valve to the left toward the word "SOAP".
Chemical will draw accurately only in the "LOW" pressure setting of your pressure gun. To activate the "LOW"
pressure, pop the collar of the gun out.
In "LOW" pressure, apply chemical to the walls and fixtures starting from the lowest point to the highest.
Spray the floor as you make your way out of the room.
Allow the chemical to dwell according to the chemical manufacturers recommendations.
You may use the brush on your squeegee/brush wand to agitate particularly soiled areas.
When you are ready to rinse away the chemical, simply turn the chemical dispensing valve to the word "RINSE".
Set your pressure gun to the desired pressure and angle of spray by adjusting the collar. Rinse surfaces starting
from the top down.
See "Recovering liquid" for final steps.
Recovering liquid from hard surfaces
The CR2 is equipped with two dedicated tools for liquid recovery: The squeegee/brush wand and the Gulper tool.
Connect recovery vacuum hose to the waste tank inlet barb.
Place the vacuum switch into the "ON" position.
Using either the squeegee/brush wand or the Gulper tool, to extract the liquid from the surface.
Monitor the levels in the recovery tank and empty as necessary. Use defoamer to ensure your vacuum motor
does not take in foam/fluid.
Using the blower feature
To use this feature, connect the Blower hose to the vacuum exhaust outlet barb and turn on the vacuum motor.
Convenient for:
.
Blowing fluid off countertops and walls onto the floor
.
Drying taps and other fixtures
.
Blowing off dust
NOTE: Do not leave the blower hose on during normal extraction as it will restrict suction