How to Use the Relay Outputs
The 3G Auto Dialler has two relay outputs which can be used to switch on external electric
devices such as lighting, sirens etc.
Relay 1 is independent and can be activated by sms message
Relay 2 is also independent but also linked to the inputs and will go on for 30 seconds when an
input is triggered
Activation by SMS Text Message (Relay 1 )
By texting the unit you can turn relay 1 & relay 2 ON or OFF individually. Below are examples
on how to do this.
#REL1=ON#
-
This will turn on relay 1
#REL1=OFF#
-
This will turn off relay 1
#REL2=ON#
-
This will turn on relay 2
#REL2=OFF#
-
This will turn off relay 2
After each operation the unit will reply with a status report REL1 ON/OFF
It is possible to pulse relay 1 & 2 for a period of 17 seconds. You will need to send a text as
follows.
#PUL=REL1#
-
This will Pulse relay 1 for 17 seconds.
#PUL=REL2#
-
This will Pulse relay 1 for 17 seconds.
.The unit will reply back REL1 or REL2 Pulse
Alarm Relay Output (Relay 2 )
Relay 2 can be used as a siren or lighting relay and will automatically come on when either
input or alarm input has been triggered for 30 seconds, please be aware of any conflicts this
may cause if you are using relay 2 as an independently activated relay.