NOTE:
(f)
Type the "stop" command to stop updating rxstatus and return to the prompt.
(11) "cnfg" Command
(a)
This command displays configurable information such as the serial port settings (protocol
and baud rate), the ICAO address, and the VFR call sign. Refer to Figure 3020.
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM INSTALLATION MANUAL
89000016
Ground stations will time out being tracked if no ADS-B uplink message is
received from the ground station for more than 40 seconds.
Figure 3019. (Sheet 1 of 1) "rxstatus" Command