Download Print this page

Menu Tree - ADTRAN 6540 SHDSL Specification

Shdsl 2-wire/4-wire ntu, ac powered

Advertisement

MENU TREE

1. LTU
1. Unit Information
2. NTU
Main Menu
1. Unit Options
2. Provisioning
2. SHDSL Options
3. G.703 Options
4. Nx64K Options
5. Test Options
1. SHDSL Port
3. Status
2. G.703 Port
3. G.703 Services
4. Nx64K Port
5. Reset All Status
4. Test
5. Performance History
1. Restart Bad Splice Detector
6. TSCAN
2. 24 Hour Counts
Local Management
7. Terminal Mode
Remote Virtual Terminal Management
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty.
6540 SHDSL 2-Wire/4-Wire NTU, AC Powered
1. Interface Mode
2. Payload Rate (kbps) *
3. SNR Margin Alarm Threshold (dB)
4. Loop Attenuation Alarm Threshold (dB)
5. Outage Auto-Retrain
1. ES 15-Minute Alarm Threshold
6. PM Thresholds
2. SES 15-Minute Alarm Threshold
3. UAS 15-Minute Alarm Threshold
4. CVC 15-Minute Alarm Threshold
5. LOSWS 15-Minute Alarm Threshold
6. OS 15-Minute Alarm Threshold
1. ISDN-PRA V3
2. G.704 CRC-4 Multiframing
3. Timeslot Idle Pattern
4. Spare Bits Insertion to Span
5. Spare Bits Pattern to Span
6. Spare Bits Insertion
7. Spare Bits Pattern
8. RAI Generation
9. E-bit Generation
10. ES 15-Minute Alarm Threshold
11. SES 15-Minute Alarm Threshold
12. UAS 15 Minute Alarm Threshold
13. CVC 15-Minute Alarm Threshold
1. Loopback Types
2. Inband Loopback Options
3. Loopback Timeout (Min)
4. BERT Pattern
5. BERT Pattern Polarity
6. Pushbuttons (All)
7. SHDSL Port Select Pushbuttons
8. V.35/V.36 RL (Circuit 140)
9. V.35/V.36 LL (Circuit 141)
10. V.35/V.36 TI (Circuit 142)
1. Unit Mode
2. Cross-Connect Map
3. Clock Source
4. Circuit ID
1. 2-Wire
5. Date and Time
2. 4-Wire
6. Restore Factory Defaults
7. Upgrade Firmware
0. Disabled
8. Local Management
1-15. Alarm Threshold
9. Change Password
0. Disabled
1-127. Alarm Threshold
1. Interface Type Auto Detection
1. Disabled
2. Interface Type Manual Select
2. Enabled
0. Disabled
3. Inactivity Alarm Delay (Secs)
1-900. Seconds
0. Disabled
4. Tx Clock Source
1-65535. Seconds
0. Disabled
5. Tx Clock Polarity
1-900. Seconds
1. Disabled
2. Enabled
6. X.21 C Mode
00h to FFh
1. Disabled
7. X.21 I Mode
2. Enabled
00h to FFh
8. V.35/V.36 RTS (Circuit 105)
1. Disabled
2. Enabled
9. V.35/V.36 RTS (Circuit 106)
00h to FFh
1. Disabled
10. V.35/V.36 RTS to CTS Delay (ms)
2. Enabled
0. Disabled
11. V.35/V.36 DSR (Circuit 107)
1-900. Seconds
0. Disabled
12. V.35/V.36 DTR (Circuit 108/2)
1-65535. Seconds
13. CVC 15-Minute Alarm Threshold
1. Dual Sided
2. Transparent
3. Nontransparent
1. PN127
1. In-band Loopback Protocol
2. V.54
1. Disabled
2. G.703 Services In-band Pattern Detection
2. Enabled
1. Disabled
3. Nx64k In-band Pattern Detection
2. Enabled
0. Disabled
1-199. Time Out in Minutes
1. ALT
2. 2047
3. 2E15-1
4. QRSS
1. Normal
1. SHDSL Local Loopback
2. Inverted
2. SHDSL Remote Loopback
3. SHDSL BERT
1. Disabled
4. G.703 Local Loopback
2. Enabled
5. G.703 BERT
1. Permanent Off
6. G.703 Services
2. DTE Driven
1. Permanent Off
7. Nx64k Local Loopback
2. Test Driven
8. Nx64k Remote Inband Loopback
9. Nx64k BERT
1. SHDSL Port
2. G.703 Port
3. Reset All
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
1. NT
2. LT
1. Internal Clock
2. Nx64 ETC(113)/X
3. G.703 Rx Clock
4. SHDSL Rx Clock
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. X.21
2. V.35
3. V.36
0. Disabled
1-100. Alarm Threshold
1. From DCE, TC (Circuit 114)
2. From DTE, ETC (Circuit 113)
1. Normal
2. Inverted
3. Auto
1. Permanent On
2. DTE Driven
1. Permanent On
2. Sync Mode
1. Permanent On
2. DTE Driven
1. Permanent Off
2. Permanent On
3. RTS Driven
0 to 255 = Delay in ms
1. Permanent Off
2. Permanent On
1. Permanent On
2. DTE Driven
1. Permanent Off
2. Permanent On
3. Sync Mode
1. Dual Sided
2. Customer Transparent
3. Customer Non-Transparent
4. Network Transparent
5. Network Non-Transparent
1. Local Loopback
2. Remote Inband Loopback
3. BERT
* 2-wire mode: 192 kbps to 2.304 Mbps (N x 64 kbps, where N=3 to 36)
4-wire mode: 384 kbps to 4.608 Mbps (N x 64 kbps, where N=even numbers, 6 to 72)
www.adtran.com
61230001L1-22B

Advertisement

loading
Need help?

Need help?

Do you have a question about the 6540 SHDSL and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

6541 shdsl6540