IMPORTANT INFORMATION
Safety First: This equipment must be operated and
maintained with the safety of the patient and doctor in mind.
1
No individual should operate table without reading and
understanding the owner's manual. Read this manual
before operating your new UMF Medical equipment.
2
Patients should only mount and dismount the table
from the front and only when the table is at a
comfortable height for their respective height.
3
This product is intended to be used for positioning
of patients during medical examinations conducted
by qualified medical personnel.
4
This manual should remain permanently affixed
or near the equipment for convenient reference.
5
Do not attempt to transport table without proper
lifting equipment.
CLASSIFICATIONS
Equipment Class — 3001 Class II, 3002 Class II, 3003 Class I
Protection against electric shock: Type B applied parts
Protection against harmful ingress of water: Ordinary Equipment
is not suitable for use in the presence of a flammable anesthetics
mixture with air or with oxygen or with nitrous oxide
Mode of Operation: Continuous operation with intermittent loading
1 minute on 9 minutes off or 2 minutes on, 18 minutes off.
The table, any manufacturer approved accessories, and all
accompanying documents are all part of the Medical Equipment
System and suitable for use within the patient environment.
This product has been evaluated with respect to electrical shock,
fire, & mechanical hazards only, in accordance with ANSI/AAMI
ES60601-1: A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, CSA
CAN/CSA-C22.2 NO. 60601-1:14, IEC 60601-1 Edition 3.1 (2012).

APPLIED PARTS

The entire table is considered to be an applied part because the patient or
practitioner could come in contact with any part of the table while in use.
It is noted that the only components designed to come in contact with the
patient on a regular occurrence are the upholstered top, leg pad, and stirrups.
6
Do not leave table with unsupervised children.
7
Use adhesive caution tape or cable runner if cord
is run across room.
8
UMF Medical reserves the right to make changes
to the design of products at any time and without notice.
9
If table becomes unresponsive while at a raised position with
a patient on the table, use a step stool, chair, or other form
of secure step to help the patient safely dismount the table.
10
Do not impede the table's movement when raising or
lowering. Doing so can cause damage to table and or
item/person in contact with table.
11
Table can be lifted from the rear underside of the body panel
(under the drawer) and in the front by pulling out the leg section
approximately 4" and using it as a hand hold. Table should
always be lifted by two people at a time that are capable of
lifting 150lbs each. Table should be lifted onto a dolly or cart
capable of holding 300lbs for transporting long distances.
29ZE
120VAC 9 AMP/220VAC 5 AMP 50-60HZ E514804
MEDICAL – GENERAL MEDICAL EQUIPMENT
AS TO ELECTRICAL SHOCK, FIRE AND MECHANICAL HAZARDS ONLY
IN ACCORDANCE WITH ANSI/AAMI ES60601-
1:A1:2012,C1:2009/®2012 AND A2:2010/®2012, CSA CAN/CSA-
C22.2 NO.60601-1:14, IEC 60601-1 EDITION 3.1 (2012), IEC 60601-
1-6:2010 (3RD EDITION) + A1:2013, IEC 62366: 2007 (1ST EDITION)
+ A1:2014