Valve Wire Sizing (Maximum One-Way Distance in Feet Between Controller and Valve)
Ground
Control Wire (ft)
Wire Size
18 AWG /
1.0 mm
18 AWG / 1.0
850
mm
16 AWG / 1.2
1040
mm
14 AWG / 1.6
1210
mm
12 AWG / 2.0
1350
mm
10 AWG / 2.5
1460
mm
8 AWG / 3
1540
mm
6 AWG / 4
1590
mm

HC - Valve Wiring

Your controller has either 6 or 12 zones depending on the model you have purchased.
There are 3 COMMON wiring points for convenience – any or all of them can be used.
Refer to the diagram below when connecting your solenoid valves to the controller. Please
click on the link below for the downloadable version of the controller to valve wiring
diagram. Hydrawise Controller Connection Diagram
16 AWG /
14 AWG /
1.2 mm
1.6 mm
1040
1210
1340
1650
1650
2150
1920
2630
2150
3080
2330
3450
2440
3700
Copyright 2020 Hunter Industries. All Rights Reserved.
12 AWG /
10 AWG /
2.0 mm
2.5 mm
1350
1460
1920
2150
2630
3080
3390
4170
4170
5400
4880
6670
5400
7690
[2]
8 AWG / 3
6 AWG / 4
mm
mm
1540
1590
2330
2440
3450
3700
4880
5400
6670
7690
8700
10530
10530
13330