Plumbing Problems; Performance Data Sheet - KitchenAid W10541605C User Manual

Table of Contents

Advertisement

Available languages

Available languages

Plumbing Problems

PROBLEM
Water Not Entering Drain
Properly
Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI Standards 42.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as
advertised.
Use replacement filter P6RFWG2K, P6RFGEG2K, P6RFKG2K,
Part Number ICE2.
Style 1 – When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter indicator
reads "REPLACE," it is recommended that you replace the filter.
Style 2 – Press FILTER to check the status of your water filter. If the
filter indicator light is yellow and the words "ORDER FILTER"
appear on the display screen, order a new filter. If the filter indicator
light is red, it is recommended that you replace the filter.
These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
® NSF is a registered trademark of NSF International.
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
RECOMMENDED SOLUTIONS
If the drain hose is not aligned over the drain, move the ice maker to align the drain.
NOTE: Service technicians cannot repair plumbing problems outside of the ice maker. Call a licensed, qualified
plumber.

PERFORMANCE DATA SHEET

Ice Maker Water Filtration System
System tested and certified by NSF
International against NSF/ANSI
Standard 42 for the reduction of
Chlorine Taste and Odor.
Average
Influent Challenge
Influent
Concentration
1.9727 mg/L
2.0 mg/L ± 10%
WARNING
Maximum
Effluent
0.71 mg/L
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
7
Average
Minimum %
Effluent
Reduction
0.7788 mg/L
70.2
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.50 gpm (1.89 Lpm) @ 60 psi
Average %
Reduction
72.81

Advertisement

Table of Contents
loading

Table of Contents