Note: To be performed by a licensed electrician only. Always use UL listed ½" (13 mm)
conduit with male adapter when installing AC wiring. Pro-HC controllers are intended to be
supplied AC power with an over-current protected device. Improper installation could result
in shock or fire hazard. This device is not intended for use by young children. Never let
children play with this device.
PRO-HC - Connecting Solenoid
Valves
1. Route valve wires between control valve location and controller.
2. At the valve location, attach a common wire to either solenoid wire of all valves. The
most commonly used color for the common wire is white. Attach a separate control wire
to the remaining wire of each valve. All wire splice connections should be done using
waterproof connectors.
3. Route valve wires through the conduit and attach conduit to one of the openings on the
bottom of the cabinet.
4. Strip 1/2" (13 mm) of insulation from ends of all wires. Secure the valve common wire
to "COM" (Common) terminal. Attach all individual valve control wires to the appropriate
station terminals.
PRO-HC CONTROLLER
Copyright 2020 Hunter Industries. All Rights Reserved.