2.4.2 Constant voltage mode
In constant voltage mode, the electronic load will consume enough current to keep the input voltage
at the set voltage.
Operating instructions: 1 Select the action item by turning the knob. 2. For parameter settings, please
refer to 1.4 Numeric Parameter Setting for details. 3. Press the
load..
2.4.3 Constant resistance mode
In constant resistance mode, the load is equivalent to a constant resistance, and the load will consume
a current that varies with the input voltage.
Operating instructions: 1 Select the action item by turning the knob. 2. For parameter settings, please
refer to 1.4 Numeric Parameter Setting for details. 3. Press the
load..
Hangzhou Zhongchuang Electronics Co., Ltd.
Figure 2.4.1 Constant current mode
Figure 2.4.2
Constant voltage mode
Figure 2.4.3 Constant resistance mode
5
corresponding【On/Off】
corresponding【On/Off】
to turn on the
to turn on the