FILTER-DRIERS

The size of the filter-drier is important. The refrigerant
charge is critical. Using an improperly sized filter-drier
will cause the ice machine to be improperly charged with
refrigerant.
Driers are covered as a warranty part. The drier must be
replaced any time the system is opened for repairs.

SUCTION CLEANUP FILTER-DRIER

Contaminated systems must have a suction line filter-drier
installed to remove contaminations. An access valve must
be installed on the inlet side of the suction filter to allow
pressure drop readings to be obtained.
Model
All Models
88

Important
Suction Line Clean-Up Filter
Drier Size
UK-165S
Part Number 000015433_03 5/20
End
Connection
Size
5/8 in.