Configuration/Installation Of The Door Contact - IRIS IRMA MATRIX R2 Mounting Manual

Option door contact
Table of Contents

Advertisement

14/22
IRMA MATRIX R2 Option Door Contact | Mounting Manual
released
2.4

Configuration/installation of the door contact

If the external door contact is activated, the control of the door information via the on-
board computer or gateway is not interpreted. The sensor is controlled only by the signals
from the external door contact.
With grouped sensors, the door contact can only be assigned to the master.
Fig. 5:
Configuration of the door contact
"Enable External Door Contact": enables the external door contact, the setting parameters
become accessible.
"Debounce Time": - response time, freely adjustable in the range from 0 to 999 ms
(recommendation: 10 ms for mechanical switches, for pneumatically operated switches a
longer period can be necessary.)
"Door Close Delay": - delay, freely adjustable in the range from 0 to 9999 ms, becomes
effective after the door is closed (1000 ms = 1 s).